EUVIMEDEUVIMED entdecken
Systematische Übersicht

Validation of accelerometry for measuring energy expenditure: a systematic review

Christiane Riedi Daniel, Linamara Rizzo Battistella

Acta Fisiátrica · 2014 · 21 (2)

DOI: 10.5935/0104-7795.20140019 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Acta Fisiátrica, 2014. Verfasst von Christiane Riedi Daniel und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The primary objective of this review was to examine the quality of the validation studies of the accelerometry tool as compared with measuring maximal oxygen uptake (VO2max). A secondary objective was to present the main characteristics of the studies and of the main models of accelerometers tested.

Method

After searching the MedLine, LILACS, Embase e CLINAHL databases with the descriptors “Oxygen Consumption” OR “Energy Metabolism” AND “Accelerometry” AND “Validation Studies,” the two authors made the selection according to the title, the abstract, and the full text. After that, the quality of the articles was assessed by the QUADAS-2 tool for risk of bias and for concerns regarding the applicability of the test.

Results

We selected 10 studies that fit the inclusion criteria. The QUADAS-2 analysis showed that for the risk of bias there were problems with identification, particularly with regard to the proposed test and with the gold standard. In relation to the applicability, in most studies the risk was low. The most used accelerometers were the Actgraph and the SenseWear Armband Pro3 that was tested in 3 studies.

Conclusion

This systematic review concluded that more information is needed about the proposed methodology in studies to classify their quality and that accelerometry is a valid alternative to measure energy metabolism in conditions of free-living and controlled activities, regardless of the accelerometer.

Zitieren

APA

Daniel, C. R., & Battistella, L. R. (2014). Validation of accelerometry for measuring energy expenditure: a systematic review. Acta Fisiátrica, 21(2). https://doi.org/10.5935/0104-7795.20140019

Vancouver

Daniel CR, Battistella LR. Validation of accelerometry for measuring energy expenditure: a systematic review. Acta Fisiátrica. 2014;21(2). doi:10.5935/0104-7795.20140019

BibTeX
@article{Daniel2014,
  author = {Daniel, Christiane Riedi and Battistella, Linamara Rizzo},
  title = {Validation of accelerometry for measuring energy expenditure: a systematic review},
  journal = {Acta Fisiátrica},
  year = {2014},
  volume = {21},
  number = {2},
  doi = {10.5935/0104-7795.20140019}
}
Kostenlos starten →