EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparison of Mechanical Performance Between Conventional Stainless Steel and 3D-Printed Cobalt–Chromium Band and Loop Space Maintainers

Jina Song, Myeongkwan Jih, Suhyun Park, Nanyoung Lee

THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY · 31.05.2026 · 53 (2) · 217-232

DOI: 10.5933/jkapd.2026.53.2.217 ↗

Kurz gefasst

Fachartikel in der Zeitschrift THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY, erschienen am 31.05.2026. Verfasst von Jina Song und 3 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Chosun University Dental Hospital.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study compared the mechanical and bonding properties of conventional stainless steel (SS) band and loop space maintainers with cobalt-chromium (Co-Cr) three-dimensional (3D)-printed appliances fabricated using selective laser melting, and evaluated the effects of loop thickness and band design. A total of 90 specimens were prepared and subjected to 5,000 thermocycles. Fracture strength was measured using a universal testing machine, and bond strength was calculated from the debonding load and bonding area. Failure modes were assessed using the adhesive remnant index and field emission scanning electron microscopy. Fracture strength significantly differed among groups (p < 0.0001). The 3D-printed 1.5 mm group showed significantly higher values than the 3D-printed 1.0 mm group (p < 0.0001). However, neither the 3D-printed 1.5 mm group nor the 3D-printed 1.0 mm group showed statistically significant differences compared with the conventional SS group (p = 0.061 and p = 0.151, respectively). For debonding load, both the conventional and 3D-printed circumferential groups showed significantly higher values than the 3D-printed partial-coverage group (p < 0.0001), with no significant difference between them. Bond strength differed significantly among groups (p = 0.015). The 3D-printed circumferential group showed significantly higher values than the partialcoverage group (p = 0.011), while no significant differences were observed between the conventional and 3D-printed groups (p = 0.360). Within the limitations of this in vitro study, the 3D-printed Co-Cr space maintainers showed no statistically significant differences in mechanical and bonding performance in several comparisons, suggesting that they may be considered an alternative to conventional space maintainers under certain conditions.

Förderung

  • Chosun University Dental Hospital

Zitieren

APA

Song, J., Jih, M., Park, S., & Lee, N. (2026). Comparison of Mechanical Performance Between Conventional Stainless Steel and 3D-Printed Cobalt–Chromium Band and Loop Space Maintainers. THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY, 53(2), 217-232. https://doi.org/10.5933/jkapd.2026.53.2.217

Vancouver

Song J, Jih M, Park S, Lee N. Comparison of Mechanical Performance Between Conventional Stainless Steel and 3D-Printed Cobalt–Chromium Band and Loop Space Maintainers. THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY. 2026;53(2):217-232. doi:10.5933/jkapd.2026.53.2.217

BibTeX
@article{Song2026,
  author = {Song, Jina and Jih, Myeongkwan and Park, Suhyun and Lee, Nanyoung},
  title = {Comparison of Mechanical Performance Between Conventional Stainless Steel and 3D-Printed Cobalt–Chromium Band and Loop Space Maintainers},
  journal = {THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY},
  year = {2026},
  volume = {53},
  number = {2},
  pages = {217--232},
  doi = {10.5933/jkapd.2026.53.2.217}
}
Kostenlos starten →