Abstract (Originalsprache)

Background

Radiopharmaceutical liquid waste requires radionuclide-specific retention, whereas decay tanks are often sized based on average wastewater flow.

Objective

To develop a patient-load-based decay tank design and operating strategy for the planned nuclear medicine facility at Bali International Hospital.

Methods

An engineering design approach integrated planned weekly patient loads, administered activities, surveyed water use, and radioactive accumulation and decay modeling. The adopted aqueous discharge criterion was 0.01 MBq/L, derived from the iodine-131 (I-131) clearance level of 10 Bq/g.

Results

The planned service profile comprised 58 diagnostic and 42 therapeutic patients per week, generating 7,750 L and 3,900 L of wastewater, respectively. Following a 10-week filling period, therapeutic effluent was modeled to have an activity concentration of 4.43 MBq/L and required 11 weeks of isolated decay. Diagnostic effluent required approximately 39.6 hours to reach the criterion; a 3-day retention period was therefore adopted. The proposed segregated configuration comprises three 40,000-L therapeutic tanks and three 10,000-L diagnostic tanks. Segregation avoids approximately 85,000 L of additional storage compared with retaining diagnostic effluent for the therapeutic decay period.

Conclusion

Patient-load profiling supports distinct capacity and rotation strategies for diagnostic and therapeutic radioactive waste. Model-predicted compliance with the discharge criterion does not, by itself, authorize discharge without activity measurement, input reconciliation, and regulatory verification.

Zitieren

APA

Tarigan, Y. D. S., & Kasih, T. P. (2026). System Design and Operational Strategy for Radiopharmaceutical Waste Decay Tanks Using Patient Load Profiling in a Hospital Nuclear Medicine Facility. Equivalent: Jurnal Ilmiah Sosial Teknik, 8(5), 2337-2349. https://doi.org/10.59261/jequi.v8i5.476

Vancouver

Tarigan YDS, Kasih TP. System Design and Operational Strategy for Radiopharmaceutical Waste Decay Tanks Using Patient Load Profiling in a Hospital Nuclear Medicine Facility. Equivalent: Jurnal Ilmiah Sosial Teknik. 2026;8(5):2337-2349. doi:10.59261/jequi.v8i5.476

BibTeX
@article{Tarigan2026,
  author = {Tarigan, Yosef Derry Sanders and Kasih, Tota Pirdo},
  title = {System Design and Operational Strategy for Radiopharmaceutical Waste Decay Tanks Using Patient Load Profiling in a Hospital Nuclear Medicine Facility},
  journal = {Equivalent: Jurnal Ilmiah Sosial Teknik},
  year = {2026},
  volume = {8},
  number = {5},
  pages = {2337--2349},
  doi = {10.59261/jequi.v8i5.476}
}
Kostenlos starten →