EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Comparison Between Awake Versus Deep Removal of I-Gel Airway in Pediatrics Undergoing Cataract Surgery: A Randomized Controlled Trial

Ahmed Hesham Hasan Houssein Masoud, Enas Aly Abd EL Motalb, Ghada Fouad Mohamed Weefky, Maha Younis Youssef Abdallah

Mansoura Medical Journal · 01.01.2026 · 56 (3)

DOI: 10.58775/2735-3990.1622 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Mansoura Medical Journal, online erschienen am 01.01.2026. Verfasst von Ahmed Hesham Hasan Houssein Masoud und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Establishing, securing, and maintaining a patent airway is essential throughout surgery under general anesthesia. The I-gel airway is a widely used supraglottic device for maintaining an open airway during anesthesia. This study aimed to compare deep versus awake removal of the I-gel airway in pediatric patients undergoing cataract surgery, with a primary focus on postoperative intraocular pressure changes.

Methods

This prospective randomized single-blind study included 48 pediatric patients (aged 4–8 years, ASA I–II) undergoing cataract surgery under general anesthesia with sevoflurane maintenance. Patients were randomly allocated into two equal groups: Group A (awake removal, n=24) and Group B (deep removal, n=24). The primary outcome was postoperative intraocular pressure change. Secondary outcomes included hemodynamic changes (heart rate, mean arterial pressure), airway hyperreactivity score, and airway-related adverse events (coughing, breath holding, laryngospasm, desaturation [SpO₂ Results: The deep removal group demonstrated a significant decrease in IOP after surgery compared to the awake removal group (14.81±1.46 vs. 15.88±1.55 mmHg, p=0.018). The absolute difference between groups was modest (1.07 mmHg). Additionally, the deep removal group showed a significant reduction in IOP from preoperative to postoperative values (pGroup A (awake removal) compared to Group B (deep removal) (HR: 108.7±11.6 vs. 98.3±9.2 beats/min, p=0.004; MAP: 77.6±8.2 vs. 69.6±7.3 mmHg, p=0.001). These differences persisted at 10 minutes post-removal (HR: 100.2±9.6 vs. 94.7±7.3 beats/min, p=0.012; MAP: 71.1±7.4 vs. 65.4±6.1 mmHg, p=0.009). Airway-related adverse events occurred more frequently in Group A (58.33%) than Group B (41.67%), though no individual complication reached statistical significance.

Conclusion

Deep removal of the I-gel airway in pediatric cataract surgery was associated with lower postoperative IOP compared with awake removal in this small randomized study, though the absolute difference was modest (1.07 mmHg) and its clinical significance remains uncertain. No statistically significant differences in individual airway complications were demonstrated, and the study may have been underpowered to detect differences in rare events. Larger adequately powered trials are required to confirm these findings and assess clinical relevance.

Zitieren

APA

Masoud, A. H. H. H., Motalb, E. A. A. E., Weefky, G. F. M., & Abdallah, M. Y. Y. (2026). Comparison Between Awake Versus Deep Removal of I-Gel Airway in Pediatrics Undergoing Cataract Surgery: A Randomized Controlled Trial. Mansoura Medical Journal, 56(3). https://doi.org/10.58775/2735-3990.1622

Vancouver

Masoud AHHH, Motalb EAAE, Weefky GFM, Abdallah MYY. Comparison Between Awake Versus Deep Removal of I-Gel Airway in Pediatrics Undergoing Cataract Surgery: A Randomized Controlled Trial. Mansoura Medical Journal. 2026;56(3). doi:10.58775/2735-3990.1622

BibTeX
@article{Masoud2026,
  author = {Masoud, Ahmed Hesham Hasan Houssein and Motalb, Enas Aly Abd EL and Weefky, Ghada Fouad Mohamed and Abdallah, Maha Younis Youssef},
  title = {Comparison Between Awake Versus Deep Removal of I-Gel Airway in Pediatrics Undergoing Cataract Surgery: A Randomized Controlled Trial},
  journal = {Mansoura Medical Journal},
  year = {2026},
  volume = {56},
  number = {3},
  doi = {10.58775/2735-3990.1622}
}
Kostenlos starten →