Short term Echocardiographic and clinical assessment of aortic valve neo-cuspidization (Ozaki procedure) in comparison with mechanical aortic valve replacement

Amr Mohamed Ahmed Elshabrawy, Mohamed A. Gabr, Eid M Daoud, Mohammed Sanad, Sherif Arafa

Mansoura Medical Journal · 01.01.2026 · 56 (1)

DOI: 10.58775/2735-3990.1597 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Medical Journal, online erschienen am 01.01.2026. Verfasst von Amr Mohamed Ahmed Elshabrawy und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Aortic valve neo-cuspidization (AVNeo, Ozaki procedure) has emerged as an alternative to conventional aortic valve replacement, aiming to preserve native aortic root dynamics and improve postoperative hemodynamics. The replacement of the aortic valve presents challenges because both biological and mechanical prostheses have notable limitations.

Aim

To evaluate the short-term clinical and echocardiographic outcomes of aortic valve neocuspidization (Ozaki procedure) compared with mechanical aortic valve replacement (AVR) in patients with isolated aortic valve disease. Patients and methods: This prospective comparative observational study included 42 adult patients with isolated aortic valve disease. 20 patients underwent AVNeo (Ozaki procedure) and 22 underwent mechanical aortic valve replacement. Echocardiographic assessment included aortic valve area (AVA), transvalvular pressure gradients, degree of aortic regurgitation, and left ventricular parameters. The operative technique was standardized for all patients according to the groups. The primary outcomes were change in the trans-aortic pressure gradients measured, change in the aortic valve area and presence and degree of aortic regurgitation by echocardiography.

Results

Postoperatively, the AVNeo group demonstrated a significantly larger AVA and lower peak and mean transvalvular pressure gradients compared with the mechanical aortic valve replacement group. Significant improvement was observed in both groups regarding echocardiographic parameters. Mild aortic regurgitation was less frequent in the AVNeo group.

Conclusion

Both procedures resulted in significant early echocardiographic improvement. AVNeo demonstrated favorable early hemodynamic performance compared with mechanical aortic valve replacement. Further studies with larger cohorts and longer follow-up are required to evaluate long-term durability and clinical outcomes.

Zitieren

APA

Elshabrawy, A. M. A., Gabr, M. A., Daoud, E. M., Sanad, M., & Arafa, S. (2026). Short term Echocardiographic and clinical assessment of aortic valve neo-cuspidization (Ozaki procedure) in comparison with mechanical aortic valve replacement. Mansoura Medical Journal, 56(1). https://doi.org/10.58775/2735-3990.1597

Vancouver

Elshabrawy AMA, Gabr MA, Daoud EM, Sanad M, Arafa S. Short term Echocardiographic and clinical assessment of aortic valve neo-cuspidization (Ozaki procedure) in comparison with mechanical aortic valve replacement. Mansoura Medical Journal. 2026;56(1). doi:10.58775/2735-3990.1597

BibTeX
@article{Elshabrawy2026,
  author = {Elshabrawy, Amr Mohamed Ahmed and Gabr, Mohamed A. and Daoud, Eid M and Sanad, Mohammed and Arafa, Sherif},
  title = {Short term Echocardiographic and clinical assessment of aortic valve neo-cuspidization (Ozaki procedure) in comparison with mechanical aortic valve replacement},
  journal = {Mansoura Medical Journal},
  year = {2026},
  volume = {56},
  number = {1},
  doi = {10.58775/2735-3990.1597}
}
Kostenlos starten →