EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Use of Coronary Sinus Diameter Measurements to Distinguish Atrioventricular Nodal Reentrant Tachycardia from Atrioventricular Reentrant Tachycardia

Mohamed Ibrahim Ataalla Khalil, Sherif Abd El Salam Sakr, Hany Mahmoud Abd Elshakour, Hoda Mohamed Sobh

Mansoura Medical Journal · 01.01.2025 · 54 (4)

DOI: 10.58775/2735-3990.1464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Medical Journal, online erschienen am 01.01.2025. Verfasst von Mohamed Ibrahim Ataalla Khalil und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Supraventricular tachycardia (SVT) is a common clinical arrhythmia, with atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular reentrant tachycardia (AVRT) being the most frequent subtypes. Distinguishing between these arrhythmias is crucial for determining the appropriate treatment strategy.

Aim

To evaluate the clinical utility of echocardiographic measurement of coronary sinus (CS) diameter in distinguishing AVNRT from AVRT.

Methods

This prospective descriptive study included 54 patients with narrow complex tachycardia who underwent echocardiography then electrophysiology study (EPS). CS diameter was measured at the ostium and 1 cm distal using 2D echocardiography then CS ostium area by 4D echocardiography was measured.

Results

Patients with AVNRT had significantly larger CS diameters by 2D echocardiography, both at ostium and 1 cm distal, compared with AVRT cases, also patients with AVNRT had significantly larger CS ostial area by 4D echocardiography compared to AVRT group. ROC analysis demonstrated that CS ostial area measured by 4D echo had the highest diagnostic accuracy.

Conclusion

Measuring the coronary sinus diameters by echocardiography, especially using 4D imaging, offers a straightforward and non-invasive method for distinguishing AVNRT from AVRT before proceeding to invasive electrophysiological studies.

Zitieren

APA

Khalil, M. I. A., Sakr, S. A. E. S., Elshakour, H. M. A., & Sobh, H. M. (2025). The Use of Coronary Sinus Diameter Measurements to Distinguish Atrioventricular Nodal Reentrant Tachycardia from Atrioventricular Reentrant Tachycardia. Mansoura Medical Journal, 54(4). https://doi.org/10.58775/2735-3990.1464

Vancouver

Khalil MIA, Sakr SAES, Elshakour HMA, Sobh HM. The Use of Coronary Sinus Diameter Measurements to Distinguish Atrioventricular Nodal Reentrant Tachycardia from Atrioventricular Reentrant Tachycardia. Mansoura Medical Journal. 2025;54(4). doi:10.58775/2735-3990.1464

BibTeX
@article{Khalil2025,
  author = {Khalil, Mohamed Ibrahim Ataalla and Sakr, Sherif Abd El Salam and Elshakour, Hany Mahmoud Abd and Sobh, Hoda Mohamed},
  title = {The Use of Coronary Sinus Diameter Measurements to Distinguish Atrioventricular Nodal Reentrant Tachycardia from Atrioventricular Reentrant Tachycardia},
  journal = {Mansoura Medical Journal},
  year = {2025},
  volume = {54},
  number = {4},
  doi = {10.58775/2735-3990.1464}
}
Kostenlos starten →