Ball-Tipped Probe Type Demonstrates Variation in Detecting Pedicle Screw Tract Breaches by Trainees in Lumbar Spine Model
SVOA Orthopaedics · 25.07.2026 · 6 (4) · 121-129
DOI: 10.58624/svoaor.2026.06.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift SVOA Orthopaedics, online erschienen am 25.07.2026. Verfasst von Mark A. Plantz und 9 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
There is a lack of research investigating the variance and accuracy of different pedicle probe designs for detecting pedicle tract breaches. This study aims to assess the accuracy of three different ball-tip probes in detecting pedicle breaches in a lumbar spine model as assessed by orthopaedic surgery trainees Methods: Pedicle tracts were created bilaterally in six lumbar Sawbones models using a 2mm drill bit. L1-L5 pedicles were randomized to no breach, superior, inferior, medial, or lateral breaches. Breach presence and location were assessed using one of three ball-tip probes with varying head diameter and shaft flexibility. Residency year, spine case logs and probe preference were recorded. Probe accuracy; level of agreement between participants by specific probe; and correlation between accuracy, case volume, and residency year were assessed.
Results
For all probes, breach detection was 80.5%, and location accuracy was 64.1%. There was no difference in breach detection between different probes. Probe B was significantly more accurate (68.8%) than probes A or C (63.3% ; 60.3%; p=0.02) in identifying breach locations. Inter-rater reliability was highest for Probe C regarding breach presence and location (k=0.24 and 0.21, respectively; fair) relative to probes A or B. Spine case logs were not correlated with the ability to identify a breach or its location. Residency year was positively correlated with identifying breach location (r=0.47, p=0.04).
Conclusion
All probes demonstrated high accuracy in breach detection, yet detecting breach location and inter-rater reliability varied between probe designs. Probe design preference did not correlate with accuracy.
Zitieren
APA
Plantz, M. A., Marx, J. S., Tegethoff, J. D., Compton, T., Carney, J. J., Gerlach, E. B., Weiner, J. A., Divi, S. N., Patel, A. A., & Hsu, W. K. (2026). Ball-Tipped Probe Type Demonstrates Variation in Detecting Pedicle Screw Tract Breaches by Trainees in Lumbar Spine Model. SVOA Orthopaedics, 6(4), 121-129. https://doi.org/10.58624/svoaor.2026.06.018
Vancouver
Plantz MA, Marx JS, Tegethoff JD, Compton T, Carney JJ, Gerlach EB, et al. Ball-Tipped Probe Type Demonstrates Variation in Detecting Pedicle Screw Tract Breaches by Trainees in Lumbar Spine Model. SVOA Orthopaedics. 2026;6(4):121-129. doi:10.58624/svoaor.2026.06.018
BibTeX
@article{Plantz2026,
author = {Plantz, Mark A. and Marx, Jeremy S. and Tegethoff, Jason D. and Compton, Tyler and Carney, John J and Gerlach, Erik B. and Weiner, Joseph A. and Divi, Srikanth N. and Patel, Alpesh A. and Hsu, Wellington K.},
title = {Ball-Tipped Probe Type Demonstrates Variation in Detecting Pedicle Screw Tract Breaches by Trainees in Lumbar Spine Model},
journal = {SVOA Orthopaedics},
year = {2026},
volume = {6},
number = {4},
pages = {121--129},
doi = {10.58624/svoaor.2026.06.018}
}
EUVIMED