EUVIMEDEUVIMED entdecken
Crossref

Retrograde Intramedullary Headless Cannulated Screw Fixation for Unstable Metacarpal Fractures: A Longitudinal Case Series Study

Leal J, Campanella S, Chávez M, Castillo R

SVOA Orthopaedics · 24.06.2026 · 6 (3) · 89-95

DOI: 10.58624/svoaor.2026.06.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SVOA Orthopaedics, online erschienen am 24.06.2026. Verfasst von Leal J und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Metacarpal fractures account for a substantial portion of upper extremity skeletal trauma. Traditional percutaneous stabilization techniques, such as Kirschner wires, often require prolonged rigid external immobilization, predisposing patients to joint stiffness and chronic tendon adhesions. Retrograde intramedullary headless cannulated screws represent a minimally invasive alternative designed to deliver absolute mechanical and rotational stability.

Objective

To evaluate the clinical, radiographic, and functional outcomes of adult patients presenting with unstable extra-articular metacarpal fractures managed via retrograde intramedullary headless cannulated screw fixation. Materials and Methods: An observational, descriptive, and retrospective longitudinal case series study was executed at the Department of Hand and Upper Limb Reconstructive Surgery of the Hospital Militar Universitario 'Dr. Carlos Arvelo', Caracas, Venezuela. A cohort of 25 adult patients (aged 20 to 60 years) treated between January 2024 and March 2025 was systematically evaluated.

Results

The study group showed a clear male predominance (84%, n=21) with a mean age of 32.4 years. The fifth metacarpal was the most frequently injured anatomical site (56%, n=14), with diaphyseal fractures accounting for 75% (n=19) of the sample. Complete radiographic bone consolidation was achieved in 100% (n=25) of the cohort, with a mean consolidation time of 6.2 weeks. Functional assessment at the final 12- week follow-up revealed an excellent mean total active range of motion (TAM) of 265°, with no reported cases of osteosynthesis material displacement, extensor tendon traction, or deep infection.

Conclusion

Retrograde intramedullary headless cannulated screw fixation constitutes a highly efficient, safe, and reproducible surgical choice for unstable extra-articular metacarpal fractures. It offers exceptional mechanical stability, avoids the need for external immobilization, and guarantees prompt, reliable functional restoration.

Zitieren

APA

J, L., S, C., M, C., & R, C. (2026). Retrograde Intramedullary Headless Cannulated Screw Fixation for Unstable Metacarpal Fractures: A Longitudinal Case Series Study. SVOA Orthopaedics, 6(3), 89-95. https://doi.org/10.58624/svoaor.2026.06.013

Vancouver

J L, S C, M C, R C. Retrograde Intramedullary Headless Cannulated Screw Fixation for Unstable Metacarpal Fractures: A Longitudinal Case Series Study. SVOA Orthopaedics. 2026;6(3):89-95. doi:10.58624/svoaor.2026.06.013

BibTeX
@article{J2026,
  author = {J, Leal and S, Campanella and M, Chávez and R, Castillo},
  title = {Retrograde Intramedullary Headless Cannulated Screw Fixation for Unstable Metacarpal Fractures: A Longitudinal Case Series Study},
  journal = {SVOA Orthopaedics},
  year = {2026},
  volume = {6},
  number = {3},
  pages = {89--95},
  doi = {10.58624/svoaor.2026.06.013}
}
Kostenlos starten →