AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Since their introduction into clinical practice two decades ago, flow diverting stents became a powerful device in endovascular treatment of different cases of complex intracranial aneurysms, especially large and giant ones. These devices provide higher coverage of the parent vessel (30–50%) compared to conventional intracranial stents, decreasing blood flow into the aneurysm and producing eventual aneurysmal thrombosis. Compared to stent-assisted coiling results in literature, they showed comparable morbidity and mortality [2,3]. However, regarding endovascular treatment of complex intracranial aneurysms arising in very large diameter vessels, (≥5.3 mm - LDV), only few devices are available on the market. We present here a case of embolization of complex large carotid aneurysm using a largest available FD stent on the market, DERIVO2, 8x50 (Acandis GmbH & Co. KG, Pforzheim, Germany).

Zitieren

APA

Medenica, S. M., Roganović, M., Radunović, A., & Borovinić, L. (2026). Ultralarge Diameter (8 mm) Derivo2 Flow Diverter for Embolisation of Giant Fusiform Carotid Aneurysm — A Case Report. SVOA Neurology, 7(4), 129-132. https://doi.org/10.58624/svoane.2026.07.018

Vancouver

Medenica SM, Roganović M, Radunović A, Borovinić L. Ultralarge Diameter (8 mm) Derivo2 Flow Diverter for Embolisation of Giant Fusiform Carotid Aneurysm — A Case Report. SVOA Neurology. 2026;7(4):129-132. doi:10.58624/svoane.2026.07.018

BibTeX
@article{Medenica2026,
  author = {Medenica, S. Milošević and Roganović, M. and Radunović, A. and Borovinić, L.},
  title = {Ultralarge Diameter (8 mm) Derivo2 Flow Diverter for Embolisation of Giant Fusiform Carotid Aneurysm — A Case Report},
  journal = {SVOA Neurology},
  year = {2026},
  volume = {7},
  number = {4},
  pages = {129--132},
  doi = {10.58624/svoane.2026.07.018}
}
Kostenlos starten →