Heat Transfer to the External Root Surface During Use of Wireless Heated Pluggers: An In Vitro Study

Joon Koh, Albert F. McMullen

SVOA Dentistry · 03.06.2026 · 7 (3) · 159-166

DOI: 10.58624/svoade.2026.07.021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SVOA Dentistry, online erschienen am 03.06.2026. Verfasst von Joon Koh und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Heat generated during thermoplastic obturation may be transferred to surrounding periodontal tissues. The purpose of this study was to evaluate the thermal behavior of wireless heated plugger systems and to determine the time required to produce a 10 °C increase in external root surface temperature, as well as the influence of dentin thickness on heat transfer.

Methods

Five wireless heated plugger systems were evaluated for plugger tip temperature profiles during 25 seconds of continuous activation. Forty extracted human teeth were instrumented to ProTaper Ultimate F3 and obturated using a warm vertical compaction technique. External root surface temperature was measured 5 mm from the apex using a thermocouple, and the time required to reach a 10 °C increase was recorded for four systems. Each specimen was tested with all systems in randomized order. Dentin thickness was measured using cone-beam computed tomography. Data were analyzed using analysis of variance with Tukey post hoc testing and linear regression (P < .05).

Results

Plugger tip temperature profiles varied among systems, with Azdent and Gutta Smart demonstrating substantial temperature overshoot exceeding 500 °C, whereas B&L Alpha II and ZARC maintained more stable temperatures near the preset value. The time required to produce a 10 °C increase differed among systems (P < .05), with Gutta Smart demonstrating the shortest mean activation time (5.2 seconds) and Azdent the longest (11.4 seconds). A significant positive association was observed between dentin thickness and time to temperature increase for all systems (R² = 0.34–0.53, P < .001).

Conclusions

Wireless heated plugger systems exhibit distinct thermal behaviors; however, plugger tip temperature does not directly predict heat transfer to the external root surface. Dentin thickness is a primary determinant of heat transfer, and careful control of activation time is recommended, particularly in teeth with reduced dentin thickness.

Zitieren

APA

Koh, J., & McMullen, A. F. (2026). Heat Transfer to the External Root Surface During Use of Wireless Heated Pluggers: An In Vitro Study. SVOA Dentistry, 7(3), 159-166. https://doi.org/10.58624/svoade.2026.07.021

Vancouver

Koh J, McMullen AF. Heat Transfer to the External Root Surface During Use of Wireless Heated Pluggers: An In Vitro Study. SVOA Dentistry. 2026;7(3):159-166. doi:10.58624/svoade.2026.07.021

BibTeX
@article{Koh2026,
  author = {Koh, Joon and McMullen, Albert F.},
  title = {Heat Transfer to the External Root Surface During Use of Wireless Heated Pluggers: An In Vitro Study},
  journal = {SVOA Dentistry},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {159--166},
  doi = {10.58624/svoade.2026.07.021}
}
Kostenlos starten →