Novel Transpatellar Tendon Retrograde Insertional Technique for Femoral Implant Placement in Rat Models
SurgiColl · 23.06.2026 · 4 (2)
DOI: 10.58616/001c.160110 ↗Kurz gefasst
Fachartikel in der Zeitschrift SurgiColl, online erschienen am 23.06.2026. Verfasst von Mohammad Javad Shariyate und 5 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Prosthetic joint infection (PJI) is a serious complication affecting arthroplasty patients. The gold-standard treatment for PJI, two-stage revision, can fail in up to 30% of cases in patients undergoing total knee arthroplasty. Current rat models of PJI following total knee arthroplasty use a mainstream retrograde femoral nailing technique that significantly damages the quadriceps-patellar complex. We describe a novel method allowing retrograde intramedullary femoral nail insertion with minimal damage to the quadriceps-patellar complex.
Methods
Our technique was performed in 48 male Sprague-Dawley rats. After proper anesthesia, a 1 cm prepatellar skin incision was made, followed by a 2 mm transpatellar tendon incision. Using fluoroscopic guidance, a 1.2mm drill bit was advanced through the patellar defect and cortical bone and was used to ream the femoral canal. A 0.8 mm stainless steel Kirschner wire was inserted through the patellar defect into the femoral canal, leaving a 1mm segment protruding in the joint space. The defects in the patellar tendon and skin were closed with sutures.
Results
The mean surgical duration was 20.3 minutes. Among the 48 rats, 47 (98%) maintained articular capsule integrity on postoperative evaluation, as confirmed by an orthopedic surgeon under loupe magnification. All rats were ambulating postoperatively.
Conclusion
This novel technique offers an efficient, minimally invasive method of retrograde femoral nail fixation that preserves the integrity of the quadriceps-patellar complex and supports the further development of simulating prosthetic knee infection models in rats.
Zitieren
APA
Shariyate, M. J., Bluman, T., Laiwala, S., Kraus, K., Young, J., & Nazarian, A. (2026). Novel Transpatellar Tendon Retrograde Insertional Technique for Femoral Implant Placement in Rat Models. SurgiColl, 4(2). https://doi.org/10.58616/001c.160110
Vancouver
Shariyate MJ, Bluman T, Laiwala S, Kraus K, Young J, Nazarian A. Novel Transpatellar Tendon Retrograde Insertional Technique for Femoral Implant Placement in Rat Models. SurgiColl. 2026;4(2). doi:10.58616/001c.160110
BibTeX
@article{Shariyate2026,
author = {Shariyate, Mohammad Javad and Bluman, Tenney and Laiwala, Shubham and Kraus, Kameron and Young, Jason and Nazarian, Ara},
title = {Novel Transpatellar Tendon Retrograde Insertional Technique for Femoral Implant Placement in Rat Models},
journal = {SurgiColl},
year = {2026},
volume = {4},
number = {2},
doi = {10.58616/001c.160110}
}
EUVIMED