EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Criterion agreement and 48-hour test–retest reliability of a microcontroller-based cadence counter during in-place running

Imran Akhmad, Suharjo Suharjo, Nurkadri Nurkadri, Hariadi Hariadi, Amirsyah Putra Lubis

Journal of Coaching and Sports Science · 16.11.2026 · 5 (4) · 31-43

DOI: 10.58524/jcss.v5i4.1492 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Coaching and Sports Science, online erschienen am 16.11.2026. Verfasst von Imran Akhmad und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Running cadence should be assessed with systems that demonstrate acceptable agreement with a reference method and adequate repeatability under the intended testing conditions.

Aim

To quantify criterion agreement with high-speed video and 48-hour test–retest repeatability of a microcontroller-based contact-mat cadence counter during controlled in-place running.

Methods

Thirty track and field athletes completed a 60-s in-place running trial on a microcontroller-based contact mat while synchronized 240-frames/s video was recorded. Independently reviewed and adjudicated video counts served as the criterion; contact-mat testing was repeated after 48 h. Agreement was assessed using ICC(A,1), absolute-error indices, and Bland–Altman statistics. Repeatability was quantified using ICC(A,1), SEM, MDC95, and session limits of agreement.

Results

Criterion ICC(A,1) was 0.995 (bootstrap 95% CI 0.990–0.997); MAE was 1.10 spm, RMSE was 1.40 spm, and MAPE was 0.63%. Mean device–video bias was −0.10 spm, with 95% limits of agreement from −2.89 to +2.69 spm. Test–retest ICC(A,1) was 0.990 (bootstrap 95% CI 0.979–0.995), with SEM of 1.44 spm and MDC95 of 3.98 spm.

Conclusions

The contact-mat counter yielded closely aligned aggregate cadence values and favorable short-interval repeatability in a fixed 60-s in-place task. These estimates are protocol-specific and do not establish interchangeability with overground running systems or performance in competition settings.

Zitieren

APA

Akhmad, I., Suharjo, S., Nurkadri, N., Hariadi, H., & Lubis, A. P. (2026). Criterion agreement and 48-hour test–retest reliability of a microcontroller-based cadence counter during in-place running. Journal of Coaching and Sports Science, 5(4), 31-43. https://doi.org/10.58524/jcss.v5i4.1492

Vancouver

Akhmad I, Suharjo S, Nurkadri N, Hariadi H, Lubis AP. Criterion agreement and 48-hour test–retest reliability of a microcontroller-based cadence counter during in-place running. Journal of Coaching and Sports Science. 2026;5(4):31-43. doi:10.58524/jcss.v5i4.1492

BibTeX
@article{Akhmad2026,
  author = {Akhmad, Imran and Suharjo, Suharjo and Nurkadri, Nurkadri and Hariadi, Hariadi and Lubis, Amirsyah Putra},
  title = {Criterion agreement and 48-hour test–retest reliability of a microcontroller-based cadence counter during in-place running},
  journal = {Journal of Coaching and Sports Science},
  year = {2026},
  volume = {5},
  number = {4},
  pages = {31--43},
  doi = {10.58524/jcss.v5i4.1492}
}
Kostenlos starten →