Design, Optimization, and Techno-Economic Analysis of a Standalone PV-Wind-Battery Microgrid for a Remote Load in Kurdistan Region of Iraq

Harwan Mohammed Taha, Laith Akram Mohammed

Mansoura Engineering Journal · 01.01.2026 · 51 (6)

DOI: 10.58491/2735-4202.3520 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Engineering Journal, online erschienen am 01.01.2026. Verfasst von Harwan Mohammed Taha und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Standalone microgrids play a crucial role in rural areas where grid electricity delivery is difficult and expensive. This research verifies the effectiveness of a standalone microgrid in a rugged area, Pers Mountain in Akre district, Duhok governorate, Iraqi Kurdistan. A first hybrid renewable energy system (HRES)-based standalone microgrid is presented to supply a remote load. Solar and wind energy are employed for their reliability, sustainability, and abundance, with battery storage ensuring continuous power when solar and wind are unavailable. Simulation results demonstrate reliable power supply during summer months (loss of power supply probability < 5%), with the system operating across three modes — PV-dominant daytime, combined wind-battery evening, and battery-discharge nighttime. The inverter achieved minimum total harmonic distortion of 1.53% for both current and voltage outputs, below the IEEE 519 limit. A full-year hourly particle swarm optimization (PSO) sizing analysis assessed annual reliability and each source's economic contribution: the original fixed sizing yields an annual loss of power supply probability (LPSP) of 26.80% (expected energy not served ~1,471 kWh/year), motivating a PSO-optimized PV-battery configuration achieving annual LPSP of 5% (~274 kWh/year unserved) at comparable cost. The site's wind resource is reasonable (13.8% capacity factor), but the fixed tower and controller cost outweighs its contribution at this small scale. The proposed HRES totals $11,960–$16,317 depending on configuration, approximately 28–38 times lower than grid extension ($455,600) to the site, while producing zero CO₂ emissions and avoiding approximately 4,189 kg/year versus an equivalent HOMER Pro-simulated diesel generator.

Zitieren

APA

Taha, H. M., & Mohammed, L. A. (2026). Design, Optimization, and Techno-Economic Analysis of a Standalone PV-Wind-Battery Microgrid for a Remote Load in Kurdistan Region of Iraq. Mansoura Engineering Journal, 51(6). https://doi.org/10.58491/2735-4202.3520

Vancouver

Taha HM, Mohammed LA. Design, Optimization, and Techno-Economic Analysis of a Standalone PV-Wind-Battery Microgrid for a Remote Load in Kurdistan Region of Iraq. Mansoura Engineering Journal. 2026;51(6). doi:10.58491/2735-4202.3520

BibTeX
@article{Taha2026,
  author = {Taha, Harwan Mohammed and Mohammed, Laith Akram},
  title = {Design, Optimization, and Techno-Economic Analysis of a Standalone PV-Wind-Battery Microgrid for a Remote Load in Kurdistan Region of Iraq},
  journal = {Mansoura Engineering Journal},
  year = {2026},
  volume = {51},
  number = {6},
  doi = {10.58491/2735-4202.3520}
}
Kostenlos starten →