AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the Enhanced Dingo Optimization Algorithm (EDOA) to reconfigure the radial distribution network with the long-standing problem of active power loss minimization while maintaining a stable and acceptable voltage profile. EDOA enhances the standard Dingo Optimization Algorithm (DOA) through the integration of adaptive search control, elite-guided local refinement, and crossover-based diversity preservation mechanisms tailored for distribution network reconfiguration problems. The proposed method has been tested on two test systems: the IEEE 33-bus standard as well as the real-world Ayepe 34-bus distribution feeder in Ibadan, Nigeria. In the IEEE 33-bus test system, EDOA reduces active power loss by 56.00%; it beats the DOA (36.76%) by 19.24 percentage points, as well as other methods such as Firefly Algorithm (32.57%), Whale Optimization (31.15%), and Grey Wolf Optimization (31.16%). EDOA is 40% faster than DOA, and it maintains all bus voltages above the safety limit of 0.95 p.u. for the IEEE 33-bus system. On the Ayepe 34-bus practical network—characterized by uneven load distribution and higher resistance-to-reactance ratios—EDOA reduces active power loss from 1003.67 kW to 804.51 kW (19.84% reduction), outperforming DOA (18.27% reduction) with improved voltage profiles at critical weak buses. The simulation results demonstrate that EDOA is effective under both benchmark and practical feeder conditions. Its fast convergence and adaptive search methods can be used as a benchmark for metaheuristic optimization on the grid.

Zitieren

APA

Ayanlade, S. O., Okakwu, I. K., Olarewaju, R. O., Okubanjo, A. A., Samson, J. B., Adebisi, O. A., Ogunwole, E. I., & Akinrogunde, O. O. (2026). Development of Enhanced Dingo Optimization Algorithm for Distribution Network Reconfiguration. Mansoura Engineering Journal, 51(3). https://doi.org/10.58491/2735-4202.3476

Vancouver

Ayanlade SO, Okakwu IK, Olarewaju RO, Okubanjo AA, Samson JB, Adebisi OA, et al. Development of Enhanced Dingo Optimization Algorithm for Distribution Network Reconfiguration. Mansoura Engineering Journal. 2026;51(3). doi:10.58491/2735-4202.3476

BibTeX
@article{Ayanlade2026,
  author = {Ayanlade, Samson Oladayo and Okakwu, Ignatius Kema and Olarewaju, Richard Oladayo and Okubanjo, Ayodeji Akinsoji and Samson, Joseph Bukola and Adebisi, Oluwadare Adepeju and Ogunwole, Emmanuel Idowu and Akinrogunde, Oluwadare Olatunde},
  title = {Development of Enhanced Dingo Optimization Algorithm for Distribution Network Reconfiguration},
  journal = {Mansoura Engineering Journal},
  year = {2026},
  volume = {51},
  number = {3},
  doi = {10.58491/2735-4202.3476}
}
Kostenlos starten →