EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Peristalsis on the Hemodynamic Analysis of Magnetohydrodynamic Jeffrey Fluid in a Two-Layered Narrow Channel

N. Lavanya, G. Ravi Kiran, M. Varun Kumar, K. Rajyalakshmi

Mansoura Engineering Journal · 03.07.2026 · 51 (4)

DOI: 10.58491/2735-4202.3437 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Engineering Journal, online erschienen am 03.07.2026. Verfasst von N. Lavanya und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, an analytical study of MHD-influenced hemodynamic of Jeffrey fluid during peristaltic transport in a two layered narrow channel is presented, a phenomenon that has substantial ramifications for microcirculatory dynamics in the cardiovascular system. The model assumes a Jeffery fluid in the core area to encapsulate microstructural phenomena, including viscosity fluctuations, whereas the periphery area is treated as a Newtonian fluid. The governing equations for both regions are simplified and analytically solved under the long wavelength approximation. Using MATHEMATICA, a numerical investigation is carried out to examine the influence of various parameters, such as the magnetic parameters, amplitude, flow flux, Jeffery fluid parameter, and the average width of the channel, on flow characteristics including core and mean haematocrit, effective viscosity. It is noticed that both the core haematocrit ( ) and the effective viscosity goes down through an increase in the average width of the channel for the Jeffery fluid, whereas they increase with increasing amplitude, magnetic parameter, and Jeffery fluid parameter. Additionally, the mean haematocrit ( ) arise with the mean half width of the channel (tube) , the Jeffery parameter ( ), the Magnetic parameter (M), and the amplitude. Furthermore, the amplitude of the peristaltic wave is found to enhance the mean haematocrit, core haematocrit and effective viscosity. These results show qualitative agreement with the Fahraeus Lindqvist effect observed in microcirculatory blood flow and provide valuable insight into blood flow dynamics in narrow arteries, thereby enhancing the understanding of complex physiological and pathological flow conditions.

Zitieren

APA

Lavanya, N., Kiran, G. R., Kumar, M. V., & Rajyalakshmi, K. (2026). Influence of Peristalsis on the Hemodynamic Analysis of Magnetohydrodynamic Jeffrey Fluid in a Two-Layered Narrow Channel. Mansoura Engineering Journal, 51(4). https://doi.org/10.58491/2735-4202.3437

Vancouver

Lavanya N, Kiran GR, Kumar MV, Rajyalakshmi K. Influence of Peristalsis on the Hemodynamic Analysis of Magnetohydrodynamic Jeffrey Fluid in a Two-Layered Narrow Channel. Mansoura Engineering Journal. 2026;51(4). doi:10.58491/2735-4202.3437

BibTeX
@article{Lavanya2026,
  author = {Lavanya, N. and Kiran, G. Ravi and Kumar, M. Varun and Rajyalakshmi, K.},
  title = {Influence of Peristalsis on the Hemodynamic Analysis of Magnetohydrodynamic Jeffrey Fluid in a Two-Layered Narrow Channel},
  journal = {Mansoura Engineering Journal},
  year = {2026},
  volume = {51},
  number = {4},
  doi = {10.58491/2735-4202.3437}
}
Kostenlos starten →