EUVIMEDEUVIMED entdecken
Crossref

Comparative Study Between HEMOTYPE SC® and Capillary Electrophoresis (MINICAP®) in Hemoglobinopathy Screening in Blood Donors at Hôpital de la Paix, Ziguinchor, Senegal

Mame Ngone COLY, Ibrahima FATY, Macoura GADJI, Ndane Niokhor DIOUF, Assangouma COLY, Alassane DIATTA

Hematology and Disorders · 2025

DOI: 10.58489/2836-3582/016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hematology and Disorders, 2025. Verfasst von Mame Ngone COLY und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Sickle cell disease (SCD) and hemoglobinopathies are among the most prevalent genetic disorders in sub-Saharan Africa. Reliable screening is critical in blood donors to ensure transfusion safety. HEMOTYPE SC®, a rapid immunochromatographic test, has been proposed as a low-cost alternative to capillary electrophoresis for large-scale screening.

Objective

This study aims to compare the performance of HEMOTYPE SC® with capillary electrophoresis (MINICAP®) for hemoglobinopathy detection in blood donors in Ziguinchor, Senegal.

Methods

A prospective cross-sectional study was conducted at Hôpital de la Paix, Ziguinchor, between January and April 2023, enrolling 398 blood donors. Hemoglobin profiles were first determined using HEMOTYPE SC®, followed by confirmation of all non-HbAA results via capillary electrophoresis (MINICAP®). Statistical concordance between the two methods was evaluated.

Results

The mean age of donors was 25 years, and 68.3% were male. Blood group O was most prevalent (44.5%). HEMOTYPE SC® detected HbAA (87.9%), HbAS (10.8%), and HbAC (1.3%), with capillary electrophoresis confirming these profiles. Additionally, 7 hemoglobin variants undetected by HEMOTYPE SC® were identified by capillary electrophoresis, and 3 hemoglobins remained unidentified.

Conclusion

HEMOTYPE SC® demonstrated high concordance with capillary electrophoresis for detecting common hemoglobin variants. However, capillary electrophoresis remains essential for quantifying hemoglobin fractions and identifying complex hemoglobinopathies.

Zitieren

APA

COLY, M. N., FATY, I., GADJI, M., DIOUF, N. N., COLY, A., & DIATTA, A. (2025). Comparative Study Between HEMOTYPE SC® and Capillary Electrophoresis (MINICAP®) in Hemoglobinopathy Screening in Blood Donors at Hôpital de la Paix, Ziguinchor, Senegal. Hematology and Disorders. https://doi.org/10.58489/2836-3582/016

Vancouver

COLY MN, FATY I, GADJI M, DIOUF NN, COLY A, DIATTA A. Comparative Study Between HEMOTYPE SC® and Capillary Electrophoresis (MINICAP®) in Hemoglobinopathy Screening in Blood Donors at Hôpital de la Paix, Ziguinchor, Senegal. Hematology and Disorders. 2025. doi:10.58489/2836-3582/016

BibTeX
@article{COLY2025,
  author = {COLY, Mame Ngone and FATY, Ibrahima and GADJI, Macoura and DIOUF, Ndane Niokhor and COLY, Assangouma and DIATTA, Alassane},
  title = {Comparative Study Between HEMOTYPE SC® and Capillary Electrophoresis (MINICAP®) in Hemoglobinopathy Screening in Blood Donors at Hôpital de la Paix, Ziguinchor, Senegal},
  journal = {Hematology and Disorders},
  year = {2025},
  doi = {10.58489/2836-3582/016}
}
Kostenlos starten →