Studi Kasus Inspeksi 4000 Jam pada Mesin Instrument Air Compressor (IAC) Atlas Copco ZR 75 Unit 2 di PT PLN Indonesia Power UBP Suralaya
JTM : JURNAL TEKNIK MESIN · 2025
DOI: 10.58466/9245b115 ↗Kurz gefasst
Fachartikel in der Zeitschrift JTM : JURNAL TEKNIK MESIN, 2025. Verfasst von Julian Muhammad Zaky und 2 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben.
Abstract (Originalsprache)
Abstrak Inspeksi berkala pada Instrument Air Compressor (IAC) berperan penting dalam menjaga kelancaran operasi pembangkit listrik. Penelitian ini mengevaluasi hasil inspeksi pada 4.000 jam operasi unit Atlas Copco ZR 75 di PT PLN Indonesia Power UBP Suralaya. Metode yang digunakan meliputi inspeksi visual, pemantauan parameter proses (tekanan, temperatur, aliran), analisis getaran, serta pemeriksaan kondisi pelumas. Hasil penelitian menunjukkan adanya penurunan efisiensi volumetrik akibat kenaikan diferensial tekanan pada filter, indikasi keausan bantalan, dan kontaminasi oli di atas ambang batas pabrikan. Rekomendasi utama adalah penggantian elemen filtrasi, pembersihan jalur intake, dan pemeriksaan bantalan. Penggabungan inspeksi berkala dengan pemantauan kondisi terbukti meningkatkan efektivitas pemeliharaan dan menekan risiko downtime. Kata kunci: Inspeksi 4000 jam, Atlas Copco ZR 75, Instrument Air Compressor, Condition Monitoring Abstract Periodic inspection of the Instrument Air Compressor (IAC) plays a crucial role in ensuring the smooth operation of power plants. This study evaluates the results of a 4,000-hour inspection of the Atlas Copco ZR 75 unit at PT PLN Indonesia Power UBP Suralaya. The methods used include visual inspection, process parameter monitoring (pressure, temperature, and flow), vibration analysis, and lubricant condition assessment. The findings indicate a decrease in volumetric efficiency due to increased differential pressure across the filters, bearing wear indications, and oil contamination exceeding the manufacturer’s threshold. The main recommendations are to replace filtration elements, clean the intake line, and inspect the bearings. The integration of periodic inspection with condition monitoring has proven effective in improving maintenance performance and minimizing downtime risk. Keywords: 4000-hour inspection, Atlas Copco ZR 75, instrument air compressor, condition monitoring
Zitieren
APA
Zaky, J. M., Abdillah, H., & Rakhmawan, R. (2025). Studi Kasus Inspeksi 4000 Jam pada Mesin Instrument Air Compressor (IAC) Atlas Copco ZR 75 Unit 2 di PT PLN Indonesia Power UBP Suralaya. JTM : JURNAL TEKNIK MESIN. https://doi.org/10.58466/9245b115
Vancouver
Zaky JM, Abdillah H, Rakhmawan R. Studi Kasus Inspeksi 4000 Jam pada Mesin Instrument Air Compressor (IAC) Atlas Copco ZR 75 Unit 2 di PT PLN Indonesia Power UBP Suralaya. JTM : JURNAL TEKNIK MESIN. 2025. doi:10.58466/9245b115
BibTeX
@article{Zaky2025,
author = {Zaky, Julian Muhammad and Abdillah, Hamid and Rakhmawan, Rakhmawan},
title = {Studi Kasus Inspeksi 4000 Jam pada Mesin Instrument Air Compressor (IAC) Atlas Copco ZR 75 Unit 2 di PT PLN Indonesia Power UBP Suralaya},
journal = {JTM : JURNAL TEKNIK MESIN},
year = {2025},
doi = {10.58466/9245b115}
}
EUVIMED