EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Static Analysis and Experimental Validation of Containerized Fire Pump Stations

Firmansah Firmansah, Adyana Adyana, T. Ardiansyah

Jurnal Locus Penelitian dan Pengabdian · 05.06.2026 · 5 (6) · 3988-3998

DOI: 10.58344/locus.v5i6.5679 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Locus Penelitian dan Pengabdian, online erschienen am 05.06.2026. Verfasst von Firmansah Firmansah und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Containerized fire pump stations repurpose ISO 40ft High Cube containers but require large openings for ventilation and access, altering structural stiffness. his study evaluates a modified container under three load cases: LC2 (dynamic lifting, 1.2g), LC3 (static operation), and LC4 (2-tier stacking, 1.8g). A mesh convergence study established a reference mesh with maximum element size h = 20 mm. Validation was performed by comparing incremental deflections at six measurement points (T1–T6) between FEA and a workshop static test under LC3, using Mean Absolute Percentage Error (MAPE) as the accuracy metric. The validated model achieved a global MAPE (T1–T4) of 10.01%, indicating adequate agreement in global stiffness. For the reference mesh, key results are: LC3 – ovm,max = 161.56 MPa, omax = 2.69 mm, SFdesign,min = 1.55; LC2 – ovm,max = 236.71 MPa, omax = 3.40 mm, SFdesign,min = 1.14; LC4 – ovm,max = 296.21 MPa, omax = 2.86 mm, SFdesign,min = 1.16. Stress hotspots are localized around openings, showing indications of spot stress/singularity; therefore, structural interpretation focuses on global response and nominal stresses in primary load-carrying members. The integration of NFPA 20 ventilation and access requirements with ISO 1496-1-based structural assessment is feasible using a validated FEA model. The modified container meets yield and deflection limits, providing defensible operational limits for lifting and 2-tier stacking under controlled dynamic factors.

Zitieren

APA

Firmansah, F., Adyana, A., & Ardiansyah, T. (2026). Static Analysis and Experimental Validation of Containerized Fire Pump Stations. Jurnal Locus Penelitian dan Pengabdian, 5(6), 3988-3998. https://doi.org/10.58344/locus.v5i6.5679

Vancouver

Firmansah F, Adyana A, Ardiansyah T. Static Analysis and Experimental Validation of Containerized Fire Pump Stations. Jurnal Locus Penelitian dan Pengabdian. 2026;5(6):3988-3998. doi:10.58344/locus.v5i6.5679

BibTeX
@article{Firmansah2026,
  author = {Firmansah, Firmansah and Adyana, Adyana and Ardiansyah, T.},
  title = {Static Analysis and Experimental Validation of Containerized Fire Pump Stations},
  journal = {Jurnal Locus Penelitian dan Pengabdian},
  year = {2026},
  volume = {5},
  number = {6},
  pages = {3988--3998},
  doi = {10.58344/locus.v5i6.5679}
}