AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Voltage sags can disrupt industrial processes by reducing motor torque, causing contactor dropout, and triggering malfunctions in sensitive control systems and power electronic equipment. This study evaluated the performance of a dynamic voltage restorer (DVR) in mitigating voltage sags on a 20-kV distribution feeder supplying a dolomite processing facility with a connected load capacity of 555 kVA. The MATLAB/Simulink model incorporated a 630-kVA, 20-kV/400-V distribution transformer and an operating point derived from customer automatic meter reading (AMR) data, comprising an active power of 416.8 kW, reactive power of 124.0 kVAr, apparent power of 433.6 kVA, and a power factor of 0.947. A balanced three-phase voltage sag lasting 0.10 s was simulated, and the load voltage was assessed under uncompensated and DVR-compensated conditions. The voltage sag reduced the line-to-line load voltage from 406.57 V to 345.35 V, corresponding to a sag depth of 15.06% and a retained voltage of 84.94%. Following DVR activation, the load voltage increased to 404.82 V. The DVR compensated for 59.47 V of the 61.22-V voltage reduction, achieving a voltage restoration level of 99.57% relative to the pre-sag voltage, a sag mitigation effectiveness of 97.15%, and a residual voltage error of 0.43%. These findings demonstrated that series voltage injection effectively restored the industrial load voltage to near its pre-sag level, providing a technical basis for evaluating DVR applications in utility-supplied medium-voltage distribution systems serving industrial facilities.

Zitieren

APA

Budiman, H. A., & Abduh, S. (2026). Performance Evaluation of A Dynamic Voltage Restorer for Voltage Sag Mitigation in a 20-kV Feeder Supplying a 555-kVA Connected Dolomite Industrial Installation. Jurnal Locus Penelitian dan Pengabdian, 5(11), 10455-10465. https://doi.org/10.58344/locus.v5i11.6541

Vancouver

Budiman HA, Abduh S. Performance Evaluation of A Dynamic Voltage Restorer for Voltage Sag Mitigation in a 20-kV Feeder Supplying a 555-kVA Connected Dolomite Industrial Installation. Jurnal Locus Penelitian dan Pengabdian. 2026;5(11):10455-10465. doi:10.58344/locus.v5i11.6541

BibTeX
@article{Budiman2026,
  author = {Budiman, Hadroh Ahmad and Abduh, Syamsir},
  title = {Performance Evaluation of A Dynamic Voltage Restorer for Voltage Sag Mitigation in a 20-kV Feeder Supplying a 555-kVA Connected Dolomite Industrial Installation},
  journal = {Jurnal Locus Penelitian dan Pengabdian},
  year = {2026},
  volume = {5},
  number = {11},
  pages = {10455--10465},
  doi = {10.58344/locus.v5i11.6541}
}
Kostenlos starten →