Comparison of incentive spirometry and oscillating positive expiratory pressure devices for pulmonary rehabilitation after coronary artery bypass graft surgery
Cardiovascular Journal of Africa · 2025
DOI: 10.5830/cvja-2025-067 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Cardiovascular Journal of Africa, 2025. Verfasst von Ali Bolat und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Ankara Etlik City Hospital, Ankara, Turkey. Hauptthemen laut MEDLINE: Coronary Artery Bypass, Spirometry, Coronary Artery Disease, Lung.
Abstract (Originalsprache)
OBJECTIVE: Coronary artery bypass graft (CABG) surgeries, which are used in the treatment of coronary artery disease are still generally performed under cardiopulmonary bypass (CPB). In addition to the mechanical effects of the surgery, pulmonary complications due toCPB are common. This study aimed to compare the effects of incentive spirometry (IS) and oscillating positive expiratory pressure (OPEP) devices used after CABG surgery on pulmonary system rehabilitation. METHODS: Two hundred and fifty-three coronary artery disease patients who underwent CABG were analysed retrospectively. The patients were divided into two groups: those using IS (n = 52) devices and those using OPEP (n = 52) devices. Arterial blood gases were evaluated on the 1st, 2nd, and 3rd postoperative days, and the 6-minute walking test (6MWT) was performed on the 2nd and 3rd postoperative days. RESULTS: The PO2, PCO2, and SaO2 values measured on the 2nd and 3rd postoperative days showed significant improvement in Group OPEP compared to Group IS (p = 0.016, 0.006, 0.031,0.039, 0.022, and 0.003, respectively). As a result of 6MWT performed on the 2nd and 3rd postoperative days, walking distance increased more in Group OPEP compared to Group IS (p < 0.001 and 0 < 0.001, respectively). In Group OPEP, both the length of stay in the intensive care unit and the length of hospital stay were found to be lower (p = 0.005 and p < 0.001, respectively). CONCLUSION: As a result of this study, we think that the use of OPEP devices in pulmonary rehabilitation will be beneficial in preventing pulmonary complications after CABG. Abbreviations: ABG: Arterıal blood gas, CABG: Coronary artery bypass graft, CAD: Coronary Artery Disease, COPD: Chronic Obstructive Pulmonary Disease, CPB: Cardiopulmonary Bypass, DM: Diabetes mellutus, ECHO: Echocardiography, EF: Ejection Fraction, EPAP: Expiratory positive airway pressure, EZPAP: Positive Airway Pressure Therapy System, FEV1: Volume Of Air Exhaled İn The 1st Second Of Forced Expiration, HL: Hyperlipidaemia, HT: Hypertension, IS: Incentive Spirometry, MİN: MİNİMUM, MAX: MAXİMUM, IMA: İnternal Mammary Artery, OPEP: Oscillating Positive Expiratory Pressure, PAD: Peripheral artery disease, PEFR: Peak Expiratory Flow Rate, PEP: Positive Expiratory Pressure, RD: Renal dysfunction, STD: Standard Deviation, 6MWT: 6 Minutes Walking Test.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Ankara Etlik City Hospital, Ankara, Turkey.
- Department of Cardiovascular Surgery, Eskişehir City Hospital, Eskişehir, Turkey.
- Department of Cardiovascular Surgery, Eskişehir City Health Practice and Research Centers, University of Health Sciences, Eskişehir, Turkey. Email: dr.aselimkocaoglu@gmail.com.
- Department of Cardiovascular Surgery, Eskişehir City Hospital, Eskşehir, Turkey.
- Department of Cardiovascular Surgery, Van Yuzuncu Yıl University Hospital, Van, Turkey.
- Department of Cardiovascular Surgery, Eskişehir City Health Practice and Research Centers, University of Health Sciences, Eskişehir, Turkey.
Zitieren
APA
Bolat, A., Gültekin, Y., Kocaoğlu, A. S., Özbayburtlu, M., Demirel, A., Atabey, R. D., & Kaya, İ. Ç. (2025). Comparison of incentive spirometry and oscillating positive expiratory pressure devices for pulmonary rehabilitation after coronary artery bypass graft surgery. Cardiovascular Journal of Africa. https://doi.org/10.5830/cvja-2025-067
Vancouver
Bolat A, Gültekin Y, Kocaoğlu AS, Özbayburtlu M, Demirel A, Atabey RD, et al. Comparison of incentive spirometry and oscillating positive expiratory pressure devices for pulmonary rehabilitation after coronary artery bypass graft surgery. Cardiovascular Journal of Africa. 2025. doi:10.5830/cvja-2025-067
BibTeX
@article{Bolat2025,
author = {Bolat, Ali and Gültekin, Yildirim and Kocaoğlu, Alper Selim and Özbayburtlu, Merih and Demirel, Abdurrahman and Atabey, Rukiye Derin and Kaya, İbrahim Çağrı},
title = {Comparison of incentive spirometry and oscillating positive expiratory pressure devices for pulmonary rehabilitation after coronary artery bypass graft surgery},
journal = {Cardiovascular Journal of Africa},
year = {2025},
doi = {10.5830/cvja-2025-067}
}
EUVIMED