Point-of-care testing compared to gold-standard laboratory methods in the measurement of serum lipids
Cardiovascular Journal of Africa · 2025
DOI: 10.5830/cvja-2023-039 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Cardiovascular Journal of Africa, 2025. Verfasst von Brett S Mansfield und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endocrinology and Metabolism, Department of Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Af…. Hauptthemen laut MEDLINE: Point-of-Care Testing, Lipids, Dyslipidemias. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
BACKGROUND: Cardiovascular disease is the leading cause of mortality worldwide, with dyslipidaemia being one of the major risk factors. Point-of-care testing (POCT) allows for the rapid measurement of serum lipids. The aim of this study was to assess the accuracy of serum lipid measurement by the Fujifilm™ NX700 POCT compared to a gold-standard clinical laboratory method (Medpace, Leuven, Belgium). METHODS: This was a prospective, observational study conducted at the Lipid Clinic at Charlotte Maxeke Johannesburg Academic Hospital from July to September 2022. Participants were known to have a lipid disorder, most commonly, familial hypercholesterolaemia. Samples sent for lipid measurement by standard laboratory methods were simultaneously measured by the Fujifilm™ NX700 POCT. RESULTS: Lipograms evaluating total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C) and calculated low-density lipoprotein cholesterol (LDL-C) were obtained from 115 participants. No statistically significant difference was noted between the parameters tested on the different platforms. The Fujifilm™ NX700 POCT correctly identified > 91% of serum lipid results as normal or abnormal, as defined by NCEP-ATP III criteria, and exhibited good sensitivity and specificity for each parameter. Lin's concordance correlation coefficient demonstrated a strong correlation for all parameters; TC (ρc = 0.9861), HDL-C (ρc = 0.95919), LDL-C (ρc = 0.98134) and TG (ρc = 0.92775). Bland-Altman plots identified low bias and a good level of agreement between the two test methods. CONCLUSION: The Fujifilm™ NX700 POCT compared favourably with gold-standard laboratory methods in the determination of serum lipid measurements, allowing for rapid screening at the primary healthcare level.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Endocrinology and Metabolism, Department of Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa. Email: brett.mansfield@wits.ac.za.
- Division of Endocrinology and Metabolism, Department of Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa.
Zitieren
APA
Mansfield, B. S., Stevens, B., Raal, F. J., & Mohamed, F. (2025). Point-of-care testing compared to gold-standard laboratory methods in the measurement of serum lipids. Cardiovascular Journal of Africa. https://doi.org/10.5830/cvja-2023-039
Vancouver
Mansfield BS, Stevens B, Raal FJ, Mohamed F. Point-of-care testing compared to gold-standard laboratory methods in the measurement of serum lipids. Cardiovascular Journal of Africa. 2025. doi:10.5830/cvja-2023-039
BibTeX
@article{Mansfield2025,
author = {Mansfield, Brett S and Stevens, Belinda and Raal, Frederick J and Mohamed, Farzahna},
title = {Point-of-care testing compared to gold-standard laboratory methods in the measurement of serum lipids},
journal = {Cardiovascular Journal of Africa},
year = {2025},
doi = {10.5830/cvja-2023-039}
}
EUVIMED