EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Optimizing Heritage Power Distribution Using Zonal TM/TR-Package Systems

Suparjo Suparjo, R. Kun Wardana Abyoto, Hendro Tjahjono

International Journal of Engineering Continuity · 08.03.2026 · 5 (1) · 88-103

DOI: 10.58291/ijec.v5i1.525 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Engineering Continuity, online erschienen am 08.03.2026. Verfasst von Suparjo Suparjo und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrical power distribution in heritage conservation areas faces the dual challenge of meeting modern technical standards while adhering to strict preservation regulations. Traditional centralized low-voltage systems often result in critical voltage drops and power losses due to extended feeder lengths. This study proposes and evaluates an optimized Zonal TM/TR-Package distribution system as a solution. Using ETAP 22.5 software, a comparative load flow analysis was conducted on a 20-hectare government heritage complex comprising 21 protected buildings. The simulation results confirm that the proposed zonal configuration significantly outperforms the existing centralized system, reducing maximum voltage drops from 12.04% to 4.48% and decreasing total active power losses (I2R) by 47.6%, and improving system efficiency from 95.32% to 97.50%, ensuring full compliance with PUIL 2020 safety standards. Critically, the reliability assessment — evaluated using SAIDI and SAIFI indices — demonstrates a 37.44% improvement in SAIDI (from 9.27 to 5.80 hours/customer/year), while SAIFI remains stable at 0.77 interruptions/customer/year, confirming that zonal fault isolation substantially reduces outage duration without increasing interruption frequency. Furthermore, the modular design minimizes physical footprint, preserving the site’s aesthetic value. Beyond a case study, this research contributes to electrical engineering science by establishing a replicable technical framework for revitalizing heritage infrastructure, balancing efficient power delivery with architectural conservation.

Zitieren

APA

Suparjo, S., Abyoto, R. K. W., & Tjahjono, H. (2026). Optimizing Heritage Power Distribution Using Zonal TM/TR-Package Systems. International Journal of Engineering Continuity, 5(1), 88-103. https://doi.org/10.58291/ijec.v5i1.525

Vancouver

Suparjo S, Abyoto RKW, Tjahjono H. Optimizing Heritage Power Distribution Using Zonal TM/TR-Package Systems. International Journal of Engineering Continuity. 2026;5(1):88-103. doi:10.58291/ijec.v5i1.525

BibTeX
@article{Suparjo2026,
  author = {Suparjo, Suparjo and Abyoto, R. Kun Wardana and Tjahjono, Hendro},
  title = {Optimizing Heritage Power Distribution Using Zonal TM/TR-Package Systems},
  journal = {International Journal of Engineering Continuity},
  year = {2026},
  volume = {5},
  number = {1},
  pages = {88--103},
  doi = {10.58291/ijec.v5i1.525}
}
Kostenlos starten →