The Total Focusing Method (TFM) is widely recognized as an advanced imaging algorithm in ultrasonic non-destructive testing (NDT), providing high spatial resolution and detailed flaw visualization. However, inconsistencies in TFM implementation, calibration, and reporting practices continue to limit reproducibility and hinder meaningful comparisons across laboratories and industrial applications. This study explores three key aspects of TFM implementation: (1) the practical differences observed when TFM is applied for flaw detection versus flaw sizing, (2) the influence of amplitude fidelity and grid resolution on quantitative image accuracy, and (3) the effect of wave-mode selection on flaw characterization. A combined simulation and experimental investigation was conducted. Semi-analytical simulations were performed using CIVA software to evaluate the influence of wave-mode selection, amplitude fidelity, and grid resolution on TFM imaging. The results highlight how variations in amplitude fidelity and wave-mode selection can affect detection sensitivity and flaw dimension estimation.
Zitieren
APA
Bajgholi, M. E., Rousseau, G., Ginzel, E., Viens, M., & Krause, T. W. (2026). Clarifying Critical Parameters in Total Focusing Method Implementation for Advanced Ultrasonic Testing Performance in Industrial Application: Case study in Centreline Crack. Research and Review Journal of Nondestructive Testing, 4(1). https://doi.org/10.58286/34107
Vancouver
Bajgholi ME, Rousseau G, Ginzel E, Viens M, Krause TW. Clarifying Critical Parameters in Total Focusing Method Implementation for Advanced Ultrasonic Testing Performance in Industrial Application: Case study in Centreline Crack. Research and Review Journal of Nondestructive Testing. 2026;4(1). doi:10.58286/34107
BibTeX
@article{Bajgholi2026,
author = {Bajgholi, Mohammad Ebrahim and Rousseau, Gilles and Ginzel, Edward and Viens, Martin and Krause, Thomas W.},
title = {Clarifying Critical Parameters in Total Focusing Method Implementation for Advanced Ultrasonic Testing Performance in Industrial Application: Case study in Centreline Crack},
journal = {Research and Review Journal of Nondestructive Testing},
year = {2026},
volume = {4},
number = {1},
doi = {10.58286/34107}
}
EUVIMED