EUVIMEDEUVIMED entdecken
Crossref

FBG PIC-based interrogators for SHM applications

Shaojie Xu, Antonio Fernández López, Irene Olivares sanchez-mellado

e-Journal of Nondestructive Testing · 2026-08 · 31 (8)

DOI: 10.58286/33881 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-08. Verfasst von Shaojie Xu und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Structural Health Monitoring (SHM) techniques based on wave propagation demands high performance interrogators with high bandwidth, high accuracy, and, simultaneously, low weight, size and price. This combination of challenging requirements for traditional off-chip solutions motivates the development of integrated photonic interrogators, which can deliver high performance in a compact, scalable and cost-effective platform. It is proposed a photonic-integrated-circuit (PIC) interrogator tailored for Fiber Bragg Grating (FBG) for SHM requirements, as following: (i) interrogation bandwidth (kHz–MHz), (ii) accuracy and sensitivity at least of 0.01-pm wavelength-shift resolution (≈ few-to-10 nε), and (iii) capable of multiplexing several FBG sensors on a single fiber. The architecture uses edge-filter demodulation: FBG-reflected power is converted to intensity by a designed on-chip spectral transfer function whose local slope around each operating point sets the sensitivity, while the linear span of that slope sets dynamic range. We formalize the intrinsic trade-off between steep slope (sensitivity) and broad linearity (range). For that purpose, a modular synthesis approach cascades and/or parallels basic building blocks—Mach Zender interferometers (MZI), ring resonators, and Bragg sections—and uses numerical optimization (fitting, correlation-based objectives) over path-length differences, coupling coefficients, resonance orders, and grating periods. While this approach increases die area, it automates re-targeting to different FBGs and simplifies tolerance management at the component level. We analyse sensitivity, linear-range and outline multiplexed operation to distinct FBG channels for WDM-style simultaneous readout. Attention is also devoted to the impact of temperature variations and fabrication tolerances on the spectral response of PIC-based interrogators, with focus on interferometric or resonant filtering structures. The thermal dependence and fabrication robustness of these architectures is analysed, highlighting its impact on interrogation stability and accuracy. Based on this analysis, different design-level strategies to reduce thermal sensitivity and widen fabrication tolerances will be discussed, providing solutions towards integrated FBG interrogation systems and minimizing the needs for complex isolation/active temperature control. Finally, experimental measurements of Lamb waves in composite plates with hybrid system FBG/PZT will be presented, in order to compare with traditional PZT based SHM systems. The test campaign will take into account relevant performance metrics for SHM applications such as wavelength-shift resolution, sensitivity, usable linear range, dynamic strain measurement bandwidth, and robustness to thermal drift will be discussed.

Zitieren

APA

Xu, S., López, A. F., & sanchez-mellado, I. O. (2026). FBG PIC-based interrogators for SHM applications. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33881

Vancouver

Xu S, López AF, sanchez-mellado IO. FBG PIC-based interrogators for SHM applications. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33881

BibTeX
@article{Xu2026,
  author = {Xu, Shaojie and López, Antonio Fernández and sanchez-mellado, Irene Olivares},
  title = {FBG PIC-based interrogators for SHM applications},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {8},
  doi = {10.58286/33881}
}
Kostenlos starten →