FBG-based guided wave mode separation
e-Journal of Nondestructive Testing · 2026-08 · 31 (8)
DOI: 10.58286/33823 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-08. Verfasst von Pawel Kudela und 5 weiteren Autor:innen.
Abstract (Originalsprache)
This paper explores guided wave propagation in a square aluminum beam through both numerical and experimental methods. The damaged and healthy conditions of the aluminum beam were considered for the analysis. Damage was modeled experimentally and numerically in the form of an open crack. The guided waves are excited by a piezoelectric disc bonded to the beam at the front face. The aim is to determine the optimal placement of fibre optic strain sensors to enable the separation of propagating guided wave modes. Mode separation is crucial because it simplifies the signal processing required for damage detection. To achieve high sensitivity to guided waves with amplitudes in the nanometre range, fibre Bragg grating (FBG) sensors combined with an edge filtering method were utilised. The advantage of FBG sensors in comparison to piezoelectric transducers (PZTs) is that FBGs can be embedded into composite laminates without a detrimental effect on their strength. Complementary measurements were taken using scanning laser Doppler vibrometry, allowing full wavefield analysis. Additionally, numerical simulations of elastic wave generation and sensing were conducted using COMSOL software. A 3D model is applied with electromechanical coupling, which includes asymmetry caused by the shape of PZT (simulating wrap-around electrode). The focus of this research is on the potential for sensing symmetric and antisymmetric guided wave modes with mode separation capabilities. For this purpose, a series of FBG sensors positioned on the perimeter of the specimen are employed. Methodology An aluminium beam measuring 2 m × 0.01 m × 0.01 m was used for both experimental and numerical investigations. A crack with a depth of 2.5 mm was introduced at a location 1.2 m from the left end of the beam. In the experimental setup, an actuator was mounted on the front face of the beam to excite guided waves using a PZT transducer. It should be noted that the wrap-around electrode and solder material used in the PZT actuator introduce asymmetries. Wave responses along the beam were captured using scanning laser Doppler vibrometry. The acquired signals were band-pass filtered around the respective carrier frequencies. A five-cycle Hann-windowed sinusoidal tone burst with a carrier frequency of 50 kHz was generated using a waveform generator, and the excitation signal was amplified tenfold using a voltage amplifier. The sampling rate was set to 1.28 MHz. Results The experimental results were compared with the numerical simulations. The waterfall plot for guided wave propagation from experimental measurements and numerical simulations show two guided wave modes, A0 and S0. A very good match of velocities between experiment and numerical simulation is observed. Acknowledgment The authors would like to gratefully acknowledge the support given by the National Science Centre, Poland, under grant agreement no. 2020/39/B/ST8/01753 in the frame of the OPUS project entitled: "Study of elastic wave mode sensing and separation using FBG sensors for structural health monitoring".
Zitieren
APA
Kudela, P., Pillai, A. J., HASAN, M. M., Radzienski, M., Ostachowicz, W., & Wandowski, T. (2026). FBG-based guided wave mode separation. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33823
Vancouver
Kudela P, Pillai AJ, HASAN MM, Radzienski M, Ostachowicz W, Wandowski T. FBG-based guided wave mode separation. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33823
BibTeX