EUVIMEDEUVIMED entdecken
Crossref

Implementation of Distributed Fiber Optic Sensors for Structural Health Monitoring in New Bridge Structures

Aleksander Wosniok, Stephan Dunkel, Frank Basedau, Mathias Breithaupt, Christos Karapanagiotis

e-Journal of Nondestructive Testing · 2026-08 · 31 (8)

DOI: 10.58286/33814 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-08. Verfasst von Aleksander Wosniok und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Structural health monitoring has traditionally been applied primarily to existing structures that already exhibit damage or load-bearing deficits. In such cases, a customized monitoring concept is typically developed to address the specific condition of the structure. This reactive approach, however, contrasts with the objectives of predictive infrastructure management, which aim to detect changes at an early stage and support long-term planning. For new bridge constructions, a shift toward proactive and integrated monitoring is therefore highly desirable. Key requirements for such an approach include the permanent availability of pre-installed sensing technology, reliable power supply and data transmission, measurement procedures without traffic disruptions, on-demand data retrieval, and the implementation of a reference or baseline measurement immediately after construction. This baseline allows any subsequent structural changes throughout the lifecycle of the bridge to be identified with high accuracy. Moreover, comprehensive monitoring supports efficient maintenance planning by combining sensor data with traditional inspection results. New bridge structures offer ideal conditions for embedded monitoring systems, as modern, robust, and cost-effective sensors can be installed permanently and non-invasively in all relevant components, including those that will later become difficult to access. Continuous monitoring provides several key benefits as early detection of damage such as corrosion or cracking, improved planning of maintenance interventions, optimization of inspection intervals, and reduction of costs and traffic restrictions. Furthermore, real structural loads resulting from variable influences such as traffic, temperature, or wind can be recorded and analyzed in detail, supporting fatigue assessments, remaining service life predictions, and the development of digital twins. Additional advantages include the detection of overloads and unauthorized heavy transports, as well as faster structural assessment following exceptional events such as fires or slope failures. This paper presents the instrumentation of a newly constructed prestressed concrete bridge using distributed fiber optic sensing (DFOS). The fiber optic sensors were integrated into all major components of the structure, including the deck slab, abutments, and all precast girders. The fiber optic sensing cables were designed to allow flexible configuration of measurement sections. During the construction phase, verification measurements and a load test were performed to evaluate installation quality, sensor performance, and data reliability. The results demonstrate that DFOS is a powerful and practical technology for structural health monitoring of new bridge constructions and represents a key enabler for predictive maintenance management.

Zitieren

APA

Wosniok, A., Dunkel, S., Basedau, F., Breithaupt, M., & Karapanagiotis, C. (2026). Implementation of Distributed Fiber Optic Sensors for Structural Health Monitoring in New Bridge Structures. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33814

Vancouver

Wosniok A, Dunkel S, Basedau F, Breithaupt M, Karapanagiotis C. Implementation of Distributed Fiber Optic Sensors for Structural Health Monitoring in New Bridge Structures. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33814

BibTeX
@article{Wosniok2026,
  author = {Wosniok, Aleksander and Dunkel, Stephan and Basedau, Frank and Breithaupt, Mathias and Karapanagiotis, Christos},
  title = {Implementation of Distributed Fiber Optic Sensors for Structural Health Monitoring in New Bridge Structures},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {8},
  doi = {10.58286/33814}
}
Kostenlos starten →