EUVIMEDEUVIMED entdecken
Crossref

Investigation of micro ring resonator as a ultrasonic Guided wave sensor

Rohan Soman, Mariusz Zdanowicz, Adam Flilipkowski, Tomasz Osuch

e-Journal of Nondestructive Testing · 2026-08 · 31 (8)

DOI: 10.58286/33707 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-08. Verfasst von Rohan Soman und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Structural health monitoring (SHM) has a potential 13.1 times return on investment as it allows reduction in maintenance costs as well as increased service life. Several different SHM techniques have been developed trying to detect damage in the structure making use of different damage sensitive features. Based on the application demand, different sensor systems have been employed for the collection of the data. Each sensor system brings their own set of advantages and disadvantages. In the last 20 years, immense work has been carried out using optical fiber sensors (OFS) for the SHM applications. OFS are light in weight, easy to multiplex, electro-magnetically neutral and may be embedded in structures. Hence are seen as ideal sensor for structural health monitoring (SHM). Fiber Bragg grating sensors have been utilized for guided wave sensing in the edge filtering configuration, they offer several interesting opportunities such as acoustic coupling, mode filtering, and self-referencing. But they suffer from drawback such as directional sensitivity, and limited bandwidth (upto few hundred kHz). To overcome these shortcomings, a new class of OF sensors based on the micro ring resonator (MRR) is proposed. The MRR works on the principle of constructive interference where integer multiples of particular wavelength of light constructively interfere to give large reflection peaks (similar to that of the FBG sensors). The key difference, is that the FBG sensors are typically of the order of few mm (typically 10mm) while the MRR is typically about 200 times smaller (45-50 µm). This makes the MRR a really point sensor thus allowing to overcome the directional sensitivity, as well as increase the bandwidth by about 100 or so times. The MRR response under different excitations frequencies for guided wave sensing is investigated in this study.

Zitieren

APA

Soman, R., Zdanowicz, M., Flilipkowski, A., & Osuch, T. (2026). Investigation of micro ring resonator as a ultrasonic Guided wave sensor. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33707

Vancouver

Soman R, Zdanowicz M, Flilipkowski A, Osuch T. Investigation of micro ring resonator as a ultrasonic Guided wave sensor. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33707

BibTeX
@article{Soman2026,
  author = {Soman, Rohan and Zdanowicz, Mariusz and Flilipkowski, Adam and Osuch, Tomasz},
  title = {Investigation of micro ring resonator as a ultrasonic Guided wave sensor},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {8},
  doi = {10.58286/33707}
}
Kostenlos starten →