Digital vs Film Radiography Performance for High-Energy Nuclear Weld Inspection

Steven Wissels, Johan Grauls

e-Journal of Nondestructive Testing · 2026-07 · 31 (7)

DOI: 10.58286/33621 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Steven Wissels und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nuclear weld inspection requires high precision, strict safety standards, and full data traceability—criteria traditionally met by film radiography but with significant operational constraints, especially for high-energy examinations of thick stainless-steel components. To evaluate digital radiography as an ALARA-compliant alternative, a comprehensive experimental program was conducted with EDF on weld configurations representative of primary-circuit structures. Using a linear accelerator and material thicknesses up to 190 mm, the study compared film and digital under realistic nuclear conditions. Initial trials confirmed that high section thickness provided sufficient beam attenuation to safely employ a high-resolution digital detector (DXR100P-HP), enabling reliable evaluation of small-dimension defects. The test campaign included baseline detector characterization, IQI assessments, and controlled detection trials on reference calibration blocks, all under strict unsharpness limits (≤0.3 mm). Beyond achieving image quality and sensitivity comparable to film, digital radiography delivered much shorter exposure times and eliminated film-processing steps, reducing total inspection duration by more than a factor of two. With additional benefits such as improved interpretation consistency and fully digital data flow, the technique establishes a foundation for future advancements including AI-assisted analytics and predictive inspection capabilities, positioning digital radiography as a scalable, next-generation solution for nuclear weld examination.

Zitieren

APA

Wissels, S., & Grauls, J. (2026). Digital vs Film Radiography Performance for High-Energy Nuclear Weld Inspection. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33621

Vancouver

Wissels S, Grauls J. Digital vs Film Radiography Performance for High-Energy Nuclear Weld Inspection. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33621

BibTeX
@article{Wissels2026,
  author = {Wissels, Steven and Grauls, Johan},
  title = {Digital vs Film Radiography Performance for High-Energy Nuclear Weld Inspection},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {7},
  doi = {10.58286/33621}
}
Kostenlos starten →