Assessing the potential of advanced imaging with low frequency Rayleigh waves: from single beam A-scan to TFM and Phase Coherence Imaging
e-Journal of Nondestructive Testing · 2026-07 · 31 (7)
DOI: 10.58286/33449 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Florin Turcu und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Rayleigh (R) waves are mechanical waves that travel along the surface of a material while penetrating the material for about one wavelength. Rayleigh waves can be generated using a ultrasound probe and wedge at an incident angle greater than the second critical angle. The velocity is slightly slower than that of shear waves. Laboratory studies have been conducted to prove the usability of R-waves to detect surface breaking flaws in metallic structures, or to detect the level a fluid in a container, or – when used at high frequencies – to detect microcracks in aircraft fan blades. The current paper investigates the practical use of lower frequency R-waves when deployed with imaging techniques like Phase Coherence (PCI) or Total Focusing Method (TFM) on portable industrial instruments. Moreover, a standard lateral-scanning phased array probe is used with a Rexolite® wedge featuring a higher incident angle that allows R-wave generation. The setup is applied to aviation reference samples (aluminum or stainless steel) but also to welding. The parameters to be evaluated are the detection capability for small notches, the sizing capability as well as the sensitivity to the presence of other materials in the propagation path (water drops, couplant gel, coating etc).
Zitieren
APA
Turcu, F., & Côté-Vachon, R. (2026). Assessing the potential of advanced imaging with low frequency Rayleigh waves: from single beam A-scan to TFM and Phase Coherence Imaging. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33449
Vancouver
Turcu F, Côté-Vachon R. Assessing the potential of advanced imaging with low frequency Rayleigh waves: from single beam A-scan to TFM and Phase Coherence Imaging. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33449
BibTeX
@article{Turcu2026,
author = {Turcu, Florin and Côté-Vachon, Raphaël},
title = {Assessing the potential of advanced imaging with low frequency Rayleigh waves: from single beam A-scan to TFM and Phase Coherence Imaging},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {7},
doi = {10.58286/33449}
}
EUVIMED