Adapting Conventional Dual-Channel Eddy Current Instruments for Flexible Array Operation in Harsh Environments
e-Journal of Nondestructive Testing · 2026-07 · 31 (7)
DOI: 10.58286/33135 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Alexis Hernandez und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Eddy current array (ECA) probes are increasingly used in a wide range of non-destructive testing (NDT) applications, serving not as replacements but as complementary tools to conventional pencil and spot probes. Although alternative array technologies are emerging, time-multiplexed configurations remain dominant due to their simplicity and robustness. This study focuses on the electrical design of a multiplexer PCB that enables operation and control via I2C. Various coil geometries and array layouts were designed on flexible printed circuits (FPC) and optimised in terms of layers, track width, and spacing to achieve high sensitivity while maintaining spatial resolution. The array was seamlessly integrated with existing dual-channel ETher NDE hardware, allowing excitation, control and real-time data acquisition without costly hardware modification. Verification tests on carbon steel samples containing machined surface defects confirmed the correct operation of both the multiplexing circuit and the coil array, producing a C-scan where the notches on the samples are readily detectable. Preliminary high-temperature trials demonstrate the robustness of using active cooling for keeping acceptable probe temperature and its potential for future industrial deployment.
Zitieren
APA
Hernandez, A., Dobie, G., MacLeod, C. N., Gough, I., Hansen, J., & Mohseni, E. (2026). Adapting Conventional Dual-Channel Eddy Current Instruments for Flexible Array Operation in Harsh Environments. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33135
Vancouver
Hernandez A, Dobie G, MacLeod CN, Gough I, Hansen J, Mohseni E. Adapting Conventional Dual-Channel Eddy Current Instruments for Flexible Array Operation in Harsh Environments. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33135
BibTeX
@article{Hernandez2026,
author = {Hernandez, Alexis and Dobie, Gordon and MacLeod, Charles N. and Gough, Iang and Hansen, John and Mohseni, Ehsan},
title = {Adapting Conventional Dual-Channel Eddy Current Instruments for Flexible Array Operation in Harsh Environments},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {7},
doi = {10.58286/33135}
}
EUVIMED