EUVIMEDEUVIMED entdecken
Crossref

Non-destructive Evaluation of Microcracks in WC-10Co-4Cr (HVOF) Coatings using Eddy Current Testing and Induction Thermography

Niklas Steinbrecher, Hans Jürgen Maier, Sebastian Barton

e-Journal of Nondestructive Testing · 2026-07 · 31 (7)

DOI: 10.58286/33068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Niklas Steinbrecher und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tungsten carbide coatings exhibit high hardness, wear resistance and corrosion resistance. Mechanical or thermal overloads can induce microcracks that compromise coating performance, particularly in high-precision applications such as calender rolls in battery production. This study investigates the suitability of eddy current testing (ECT) and induction thermography for detecting such microcracks. C60 steel specimens coated with WC-10Co-4Cr were subjected to local tensile strains in the range of 0.15% to 0.4% and to thermal shock cycles to induce microcracks under controlled conditions. Using a high-resolution differential ECT setup, a clear correlation was observed between crack width and signal amplitude, with the smallest reliably detectable cracks measuring approximately ≈ 1.5 µm in width. Induction thermography achieved a similar sensitivity, enabling the detection of cracks with widths of approximately ≈ 1 µm. These findings highlight the complementary capabilities of eddy current testing and induction thermography for the reliable non-destructive detection and characterisation of microcracks in thermally sprayed hard coatings.

Zitieren

APA

Steinbrecher, N., Maier, H. J., & Barton, S. (2026). Non-destructive Evaluation of Microcracks in WC-10Co-4Cr (HVOF) Coatings using Eddy Current Testing and Induction Thermography. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33068

Vancouver

Steinbrecher N, Maier HJ, Barton S. Non-destructive Evaluation of Microcracks in WC-10Co-4Cr (HVOF) Coatings using Eddy Current Testing and Induction Thermography. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33068

BibTeX
@article{Steinbrecher2026,
  author = {Steinbrecher, Niklas and Maier, Hans Jürgen and Barton, Sebastian},
  title = {Non-destructive Evaluation of Microcracks in WC-10Co-4Cr (HVOF) Coatings using Eddy Current Testing and Induction Thermography},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {7},
  doi = {10.58286/33068}
}
Kostenlos starten →