Structural integrity of GFRP (Glass Fiber Reinforced Polymer) non-pressurized reactor – main aspects and case study analysis
e-Journal of Nondestructive Testing · 2026-07 · 31 (7)
DOI: 10.58286/33061 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Domenico Di Fonzo und 5 weiteren Autor:innen.
Abstract (Originalsprache)
This paper, through the analysis of management factors as root causes of an accident occurred last year in Italy, aims to present safety issues of a glass fibre reinforced polymer (GRFP) reactors (and vessels in general) and monitoring and control procedures for the ageing of their critical equipment, in accordance with Seveso regulations. Moreover, general product and process standards for composite repairs, essentials for drafting technical and application specifications, are analysed. More specifically, numerous critical factors (e.g., resin-hardener mixing ratio, resin-fibre volumetric ratio, fabric fibre type and direction, impregnation procedures, polymerisation technologies, destructive testing and CnD after polymerisation) on which the elastic behaviour and final mechanical strength of a repair (using composite materials) depend, are highlighted. Keywords: GRFP, Glass Fiber Reinforced Polymer reactor, case study, inspection, control.
Zitieren
APA
Fonzo, D. D., Augugliaro, G., quadri, F. D., Marrazzo, R., Vazzana, F., & Bartolozzi, V. (2026). Structural integrity of GFRP (Glass Fiber Reinforced Polymer) non-pressurized reactor – main aspects and case study analysis. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33061
Vancouver
Fonzo DD, Augugliaro G, quadri FD, Marrazzo R, Vazzana F, Bartolozzi V. Structural integrity of GFRP (Glass Fiber Reinforced Polymer) non-pressurized reactor – main aspects and case study analysis. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33061
BibTeX
@article{Fonzo2026,
author = {Fonzo, Domenico Di and Augugliaro, G. and quadri, Fausta Delli and Marrazzo, Romualdo and Vazzana, Fabrizio and Bartolozzi, Vincenzo},
title = {Structural integrity of GFRP (Glass Fiber Reinforced Polymer) non-pressurized reactor – main aspects and case study analysis},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {7},
doi = {10.58286/33061}
}
EUVIMED