CFD VALIDATION OF HEAT TRANSFER PERFORMANCE OF DOUBLE PIPE HEAT EXCHANGERS AS HOUSEHOLD MACHINES USED FOR HEAT RECOVERY
Scientific works/Elmi eserler · 22.07.2026 · 360
DOI: 10.58225/mpmma.2026.360 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific works/Elmi eserler, online erschienen am 22.06.2026. Verfasst von Halil Tugra Basancelebi und 3 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben.
Abstract (Originalsprache)
In this research, a theoretical and computational study on a counterflow double pipe heat exchanger with turbulent water flow is presented. The Nusselt numbers, convective heat transfer coefficients, and total heat transfer coefficients were determined based on the Dittus-Boelter correlation. NTU – ε and LMTD techniques were used to calculate outlet temperature and heat transfer rates. Results have been validated against CFD. The simulations are in good accord and confirm the trustworthiness of the theoretical approach. Water served as the practice fluids. Hot water with a mass flow rate of 0.154 kg/s and an input temperature of 67°C (340.15 K) was passed through the inner tube. The cold water was cycled in the annulus between the tubes with a mass flow rate of 0.50 kg/s and an inlet temperature 4 °C (277.15 K). The theoretical outlet temperature of the cold side was found to be 5.4°C (278.55 K) and the simulation result was 279.17 K. Theoretically, the hot side was calculated to have an exit temperature of 62.6°C (335.75 K), but the simulation result was 325.19 K with the maximum variance of 3.14%. The deviation rates were less than 5% for all the cases, which shows that the present empirical correlations can be employed with confidence for the provided boundary conditions. Thus, the developed model was proved to work well.
Zitieren
APA
Basancelebi, H. T., Ozkas, U., Gerelioglu, A., & Dalkılıc, A. S. (2026). CFD VALIDATION OF HEAT TRANSFER PERFORMANCE OF DOUBLE PIPE HEAT EXCHANGERS AS HOUSEHOLD MACHINES USED FOR HEAT RECOVERY. Scientific works/Elmi eserler, 360. https://doi.org/10.58225/mpmma.2026.360
Vancouver
Basancelebi HT, Ozkas U, Gerelioglu A, Dalkılıc AS. CFD VALIDATION OF HEAT TRANSFER PERFORMANCE OF DOUBLE PIPE HEAT EXCHANGERS AS HOUSEHOLD MACHINES USED FOR HEAT RECOVERY. Scientific works/Elmi eserler. 2026:360. doi:10.58225/mpmma.2026.360
BibTeX
@article{Basancelebi2026,
author = {Basancelebi, Halil Tugra and Ozkas, Umit and Gerelioglu, Atlas and Dalkılıc, Ahmet Selim},
title = {CFD VALIDATION OF HEAT TRANSFER PERFORMANCE OF DOUBLE PIPE HEAT EXCHANGERS AS HOUSEHOLD MACHINES USED FOR HEAT RECOVERY},
journal = {Scientific works/Elmi eserler},
year = {2026},
pages = {360},
doi = {10.58225/mpmma.2026.360}
}