Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a

Lucas Gempar Febria Nata Reksa, Wahyu Assrul Alhamsah, Supardi Supardi

Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim · 03.07.2026 · 5 (2) · 135-155

DOI: 10.58192/ocean.v5i2.4816 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim, online erschienen am 03.07.2026. Verfasst von Lucas Gempar Febria Nata Reksa und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to analyze the effects of condenser pipe configuration, refrigerant charge, and condenser airflow velocity on the performance of a refrigerator using R-600a refrigerant. The condenser pipe configurations investigated were U10, U12, and U14, with refrigerant charges of 46 g, 48 g, and 50 g, and condenser fan speeds of 1000 rpm, 1200 rpm, and 1300 rpm. The observed parameters included the refrigerant mass flow rate (ṁ), compressor work (W), condenser heat rejection capacity (Qc), and Coefficient of Performance (COP). The analysis was conducted based on enthalpy data at each point of the refrigeration cycle and the performance test results of the cooling system.The results indicate that increasing the number of condenser pipe passes and the refrigerant charge tends to enhance the condenser's heat rejection capability, thereby improving overall system performance. The optimum configuration was achieved with the U14 condenser pipe arrangement, a refrigerant charge of 50 g, and a condenser airflow velocity corresponding to a fan speed of 1300 rpm. This configuration produced a refrigerant mass flow rate of 0,0184 kg/s, compressor work of 1,32 kW, condenser heat rejection capacity of 5,65 kW, and the highest COP value of 4,28. In contrast, the lowest performance was obtained with the U10 condenser pipe arrangement, a refrigerant charge of 48 g, and a fan speed of 1000 rpm, resulting in a COP of 3,27. In general, increasing the condenser airflow velocity improved the condensation process and enhanced system efficiency, particularly for longer condenser pipe configurations. The findings demonstrate that the combination of condenser pipe configuration, refrigerant charge, and condenser airflow velocity has a significant effect on the performance and energy efficiency of an R-600a refrigerator.

Zitieren

APA

Reksa, L. G. F. N., Alhamsah, W. A., & Supardi, S. (2026). Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a. Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim, 5(2), 135-155. https://doi.org/10.58192/ocean.v5i2.4816

Vancouver

Reksa LGFN, Alhamsah WA, Supardi S. Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a. Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim. 2026;5(2):135-155. doi:10.58192/ocean.v5i2.4816

BibTeX
@article{Reksa2026,
  author = {Reksa, Lucas Gempar Febria Nata and Alhamsah, Wahyu Assrul and Supardi, Supardi},
  title = {Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a},
  journal = {Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim},
  year = {2026},
  volume = {5},
  number = {2},
  pages = {135--155},
  doi = {10.58192/ocean.v5i2.4816}
}
Kostenlos starten →