In Vitro Studies and Evaluation of Antibacterial Properties of Biodegradable Bone Joints Based on PLA/PCL/HA
Journal of Clinical Research in Paramedical Sciences · 2022
DOI: 10.5812/jcrps-124080 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Research in Paramedical Sciences, 2022. Verfasst von Farnaz Dehghani Firoozabadi und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Due to the history of using permanent implants and the ability of adaptations of polymers to physiological environments such as the body environment, the need to design a polymer implant with a new formulation for orthopedic applications was felt.
Methods
Polymer joints in this study were made by solvent casting method. The mechanical properties of the samples were investigated by bending tests, before and after immersion in simulated body fluid (SBF). Morphology of nanocomposites, bioactivity of samples and initiation of degradation process were performed by field emission scanning electron microscope (FESEM). Toxicity test was performed to evaluate the toxicity of nanocomposites. The antibacterial properties of the samples were investigated by examining the zone of inhibition and measuring the photometric concentration. Biodegradability test was performed to prove the biodegradability of polymer joints.
Results
It was found that the mechanical properties of nanostructures increased with the addition of nanoparticles. Also, the presence of oxide and graphene nanoparticles affected the antibacterial properties of the composite nanostructure. Immersion in SBF solution showed that the nanostructures were biodegradable and bioactive. The results of this study indicate that the optimal nanocomposite PLA-PCL-HA-1% ZNO-1% GR has a Young’s modulus close to spongy bone and reduces the stress shielding phenomenon. The flexural Yang modulus of the PLA-PCL-HA nanocomposite was 2139.037 ± 381.312 MPa. The presence of zinc oxide and graphene nanoparticles increased the Young’s modulus to 4363.636 ± 127.498 MPa. The optimal sample has the necessary lethality against two strains of gram-positive and gram-negative bacteria and due to its bioactivity is a suitable option for use in spongy bone tissue. In this study, the viability of fibroblast cells in the vicinity of the polymer matrix versus the optimal matrix increased from 22.14 ± 0.623 to 82.96 ± 1.101% after 72 hours.
Conclusions
Improving cell viability indicates a reduction in the optimal matrix toxicity compared to the polymer matrix.
Zitieren
APA
Firoozabadi, F. D., Saadatabadi, A. R., & Asefnejad, A. (2022). In Vitro Studies and Evaluation of Antibacterial Properties of Biodegradable Bone Joints Based on PLA/PCL/HA. Journal of Clinical Research in Paramedical Sciences. https://doi.org/10.5812/jcrps-124080
Vancouver
Firoozabadi FD, Saadatabadi AR, Asefnejad A. In Vitro Studies and Evaluation of Antibacterial Properties of Biodegradable Bone Joints Based on PLA/PCL/HA. Journal of Clinical Research in Paramedical Sciences. 2022. doi:10.5812/jcrps-124080
BibTeX
@article{Firoozabadi2022,
author = {Firoozabadi, Farnaz Dehghani and Saadatabadi, Ahmad Ramazani and Asefnejad, Azadeh},
title = {In Vitro Studies and Evaluation of Antibacterial Properties of Biodegradable Bone Joints Based on PLA/PCL/HA},
journal = {Journal of Clinical Research in Paramedical Sciences},
year = {2022},
doi = {10.5812/jcrps-124080}
}
EUVIMED