Carotid Artery Dissection After Cervical Traction Device Use: A Case Report
Clinical Practice and Cases in Emergency Medicine · 27.10.2026 · 10 (4)
DOI: 10.5811/cpcem.64694 ↗Kurz gefasst
Fallbericht in der Zeitschrift Clinical Practice and Cases in Emergency Medicine, online erschienen am 27.10.2026. Verfasst von Kian D Samadian und 5 weiteren Autor:innen. Beteiligte Einrichtung: Harvard Medical School, Boston, Massachusetts. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Internal carotid artery (ICA) dissection is a time-sensitive vascular emergency that may present with subtle findings, most notably painful Horner syndrome. Mechanical stress to the cervical vasculature is a recognized trigger for this condition. Case Report: We report a 56-year-old man who developed ipsilateral ptosis, miosis, and head and neck pain after using a home cervical traction device. Computed tomography angiography showed focal critical stenosis of the distal cervical left ICA consistent with dissection, along with a contralateral pseudoaneurysm suggesting prior injury. He was treated with dual antiplatelet therapy.
Conclusion
This case highlights a potential association between cervical traction device use and carotid dissection and underscores the importance of recognizing painful Horner syndrome and bilateral carotid pathology, while prompting clinicians to specifically inquire about traction device use.
Autor:innen und Institutionen
- Harvard Medical School, Boston, Massachusetts.
- Massachusetts General Hospital, Department of Emergency Medicine, Boston, Massachusetts.
- Massachusetts Eye and Ear, Department of Emergency Medicine, Boston, Massachusetts.
- Massachusetts Eye and Ear, Department of Ophthalmology, Boston, Massachusetts.
- Massachusetts General Hospital, Department of Neurology, Boston, Massachusetts.
- Brigham and Women's Hospital, Department of Neurology, Boston, Massachusetts.
Zitieren
APA
Samadian, K. D., Nothnagle, M. K., Mostaghimi, S. M., Alhoyek, S., Babar, R., & He, S. (2026). Carotid Artery Dissection After Cervical Traction Device Use: A Case Report. Clinical Practice and Cases in Emergency Medicine, 10(4). https://doi.org/10.5811/cpcem.64694
Vancouver
Samadian KD, Nothnagle MK, Mostaghimi SM, Alhoyek S, Babar R, He S. Carotid Artery Dissection After Cervical Traction Device Use: A Case Report. Clinical Practice and Cases in Emergency Medicine. 2026;10(4). doi:10.5811/cpcem.64694
BibTeX
@article{Samadian2026,
author = {Samadian, Kian D and Nothnagle, Maureen K and Mostaghimi, Sina M and Alhoyek, Sandra and Babar, Rehmat and He, Shuhan},
title = {Carotid Artery Dissection After Cervical Traction Device Use: A Case Report},
journal = {Clinical Practice and Cases in Emergency Medicine},
year = {2026},
volume = {10},
number = {4},
doi = {10.5811/cpcem.64694}
}
EUVIMED