Evaluation of Peak Skin Doses and Lens Doses during Interventional Neuroradiology Using a Direct Measurement System
Journal of Neuroendovascular Therapy · 2022 · 16 (10) · 491-497
DOI: 10.5797/jnet.oa.2022-0024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuroendovascular Therapy, 2022. Verfasst von Satoru Kawauchi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Toranomon Hospital, Tokyo, Japan. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
In interventional neuroradiology (INR), the evaluation of the peak skin dose (PSD) and lens dose is important because the patient radiation dose increases in cases in which the procedure is more difficult and complex. This study evaluated the radiation doses during INR procedures using a direct measurement system.
Methods
Radiation dose measurements during INR were performed in 332 patients with unruptured aneurysm (URAN), dural arteriovenous fistula (DAVF), and arteriovenous malformation (AVM). The PSD and bilateral lens doses were analyzed for each disease. The Pearson correlation test was used to determine whether the PSD and lens doses were linearly related to the reference air kerma (Ka,r).
Results
In all cases, the PSD and right and left lens doses were 2.36 ± 1.28 Gy, 114.2 ± 54.6 mGy, and 189.8 ± 160.3 mGy, respectively. The PSD and lens doses of the DAVF and AVM cases were significantly higher than those of the URAN case. The Pearson correlation test revealed statistically significant positive correlations between Ka,r and PSD, Ka,r and right lens dose, and Ka,r and left lens dose.
Conclusion
The characteristics of radiation dose in INR were clarified. Owing to the concern of increased radiation doses exceeding the threshold values in DAVF and AVM cases, protection from radiation is required. Simple regression analysis revealed the possibility of precisely predicting PSD using Ka,r.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Toranomon Hospital, Tokyo, Japan.
- Department of Radiological Technology, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
- Okinaka Memorial Institute for Medical Research, Tokyo, Japan.
- Department of Radiation Regulatory Science Research, National Institute of Radiological Sciences, National Institute for Quantum Science and Technology, Chiba, Chiba, Japan.
- Department of Endovascular Neurosurgery, Toranomon Hospital, Tokyo, Japan.
- Division for Stroke Prevention and Treatment, Department of Neurosurgery, Faculty of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Zitieren
APA
Kawauchi, S., Chida, K., Moritake, T., Hamada, Y., Yoda, S., Sakuma, H., Tsuruta, W., & Matsumaru, Y. (2022). Evaluation of Peak Skin Doses and Lens Doses during Interventional Neuroradiology Using a Direct Measurement System. Journal of Neuroendovascular Therapy, 16(10), 491-497. https://doi.org/10.5797/jnet.oa.2022-0024
Vancouver
Kawauchi S, Chida K, Moritake T, Hamada Y, Yoda S, Sakuma H, et al. Evaluation of Peak Skin Doses and Lens Doses during Interventional Neuroradiology Using a Direct Measurement System. Journal of Neuroendovascular Therapy. 2022;16(10):491-497. doi:10.5797/jnet.oa.2022-0024
BibTeX
@article{Kawauchi2022,
author = {Kawauchi, Satoru and Chida, Koichi and Moritake, Takashi and Hamada, Yusuke and Yoda, Shogo and Sakuma, Hideyuki and Tsuruta, Wataro and Matsumaru, Yuji},
title = {Evaluation of Peak Skin Doses and Lens Doses during Interventional Neuroradiology Using a Direct Measurement System},
journal = {Journal of Neuroendovascular Therapy},
year = {2022},
volume = {16},
number = {10},
pages = {491--497},
doi = {10.5797/jnet.oa.2022-0024}
}
EUVIMED