EUVIMEDEUVIMED entdecken
Crossref

Shared-Terminal Microfluidic Electrochemical Platform for Multiplex Enzyme Sensing via Ohmic-Drop-Assisted Signal Modulation

Jian XIONG, Yi DENG, Hiroaki SUZUKI, Seiya TSUJIMURA

Electrochemistry · 01.11.2026 · 94 (11) · 113001-113001

DOI: 10.5796/electrochemistry.26-74073 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electrochemistry, erschienen am 01.11.2026. Verfasst von Jian XIONG und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Accelerated Innovation Research Initiative Turning Top Science and Ideas into High-Impact Values, Japan Society for the Promotion of Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiplex electrochemical sensing typically requires either physical isolation of sensing regions or independent wiring of each electrode to avoid signal interference, which increases device complexity and limits miniaturization. Here, we propose a shared-terminal microfluidic electrochemical platform for wiring-reduced multiplex biosensing based on ohmic-drop-assisted signal modulation. In the proposed 2 × 4 device, multiple sensing regions are integrated within a serpentine microfluidic channel and connected through common working-electrode terminals, while signal addressing is achieved by switching counter/reference electrode pairs. Compared with a conventional independently wired three-electrode array, the device reduces the required external connections from 24 to 8, corresponding to a 66.7 % reduction in wiring. The confined microchannel introduces position-dependent solution resistance, resulting in different degrees of faradaic-current attenuation at different sensing regions. Geometric estimation shows that the solution resistance along the longest path can reach the megaohm range, supporting the observed strong attenuation of faradaic responses at remote sensing regions. As proof of concept, we integrated glucose oxidase/chitosan and lactate oxidase/chitosan sensing sites on the same device for glucose and lactate detection. Both sensors show concentration-dependent chronoamperometric responses with good linearity. In mixed-analyte measurements, each sensor retains its target response while showing negligible response to the non-target analyte, demonstrating selective glucose/lactate readout in a shared electrolyte environment. This shared-terminal and ohmic-drop-assisted strategy provides a simple approach for reducing wiring complexity while enabling multiplex electrochemical biosensing in microfluidic devices.

Förderung

  • Accelerated Innovation Research Initiative Turning Top Science and Ideas into High-Impact Values
  • Japan Society for the Promotion of Science

Zitieren

APA

XIONG, J., DENG, Y., SUZUKI, H., & TSUJIMURA, S. (2026). Shared-Terminal Microfluidic Electrochemical Platform for Multiplex Enzyme Sensing via Ohmic-Drop-Assisted Signal Modulation. Electrochemistry, 94(11), 113001-113001. https://doi.org/10.5796/electrochemistry.26-74073

Vancouver

XIONG J, DENG Y, SUZUKI H, TSUJIMURA S. Shared-Terminal Microfluidic Electrochemical Platform for Multiplex Enzyme Sensing via Ohmic-Drop-Assisted Signal Modulation. Electrochemistry. 2026;94(11):113001-113001. doi:10.5796/electrochemistry.26-74073

BibTeX
@article{XIONG2026,
  author = {XIONG, Jian and DENG, Yi and SUZUKI, Hiroaki and TSUJIMURA, Seiya},
  title = {Shared-Terminal Microfluidic Electrochemical Platform for Multiplex Enzyme Sensing via Ohmic-Drop-Assisted Signal Modulation},
  journal = {Electrochemistry},
  year = {2026},
  volume = {94},
  number = {11},
  pages = {113001--113001},
  doi = {10.5796/electrochemistry.26-74073}
}
Kostenlos starten →