Evaluation of the short-term safety of the protocols combining dermal fillers, energy-based devices and cosmetic products in anti-aging treatments of face and décolleté
Aesthetic Medicine · 30.09.2026
DOI: 10.57662/am.2026.18719 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aesthetic Medicine, erschienen am 30.09.2026. Verfasst von Pablo Naranjo García und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
In order to address the large number of aesthetic concerns associated with the aging process, novel therapeutic strategies started to be practiced by doctors, combining minimally or non-invasive techniques, particularly dermal fillers and energy-based devices (EBDs). The objective of this study is to evaluate the early safety of different protocols combining dermal fillers with EBDs and cosmetic products.
Methods
A prospective, single-centre, open-label, randomized study (1:1:1:1 allocation) was conducted with 128 volunteers, assigned to one of those four protocols (PA, PB, PC, PD). Each protocol incorporated a unique combination of interventions, including dermal fillers (hybrid injectable hyaluronic acid and calcium hydroxyapatite), fractional radiofrequency, monopolar capacitive-resistive radiofrequency and cosmetic products. Protocol PC included all those treatment modalities combined. Safety was assessed by monitoring local reactions at the filler injection sites and treated anatomical areas. While the complete study has a duration of 195 days, this preliminary safety study focuses on findings through day 18 after treatment initiation.
Results
On day 15, 57% of the patients experienced mild side effects at facial injection sites, with no significant differences observed between the four protocols (standalone injection treatments versus combined treatments with EBDs). Erythema and itching were the most common manifestations (20%). Regarding the décolleté, 90% of cases reported reactions, predominantly erythema (50%). By day 18 (three days after filler treatment session), 96% of subjects reported facial reactions, the majority of which were bruising or dryness. The rates of these reactions were higher in the standalone injection protocols (PA and PB groups) than in combined treatment protocols (PC and PD groups). At the décolleté, bruising was observed in 99% of the patients, with no significant intergroup differences noted.
Conclusion
In this preliminary, short-term safety analysis, combining dermal filler injections, EBDs, and cosmetic products within the same anti-aging treatment session for the face and décolleté did not appear to increase the overall burden of local reactions compared with standalone filler injections. These findings support the feasibility of further investigating same-session combination treatments, although long-term safety will need to be verified through the safety analysis at study completion.
Schlagwörter
Zitieren
APA
García, P. N., Ojeda, M. P., Buruaga, J. S. D., & Andrino, R. L. (2026). Evaluation of the short-term safety of the protocols combining dermal fillers, energy-based devices and cosmetic products in anti-aging treatments of face and décolleté. Aesthetic Medicine. https://doi.org/10.57662/am.2026.18719
Vancouver
García PN, Ojeda MP, Buruaga JSD, Andrino RL. Evaluation of the short-term safety of the protocols combining dermal fillers, energy-based devices and cosmetic products in anti-aging treatments of face and décolleté. Aesthetic Medicine. 2026. doi:10.57662/am.2026.18719
BibTeX
@article{Garca2026,
author = {García, Pablo Naranjo and Ojeda, Martin Prio and Buruaga, Juan Saenz de and Andrino, Rodolfo López},
title = {Evaluation of the short-term safety of the protocols combining dermal fillers, energy-based devices and cosmetic products in anti-aging treatments of face and décolleté},
journal = {Aesthetic Medicine},
year = {2026},
doi = {10.57662/am.2026.18719}
}
EUVIMED