Safety of Custodiol for Myocardial Protection in Minimally Invasive Mitral Valve Repair: A Japanese Single-Center Retrospective Comparison with Blood Cardioplegia in Conventional Sternotomy Repair
Annals of Thoracic and Cardiovascular Surgery · 2026
DOI: 10.5761/atcs.oa.25-00208 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Thoracic and Cardiovascular Surgery, 2026. Verfasst von Hiroaki Aizawa und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan. Hauptthemen laut MEDLINE: Cardioplegic Solutions, Heart Arrest, Induced, Heart Valve Prosthesis Implantation, Minimally Invasive Surgical Procedures. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
PURPOSE: Research regarding Custodiol's safety in minimally invasive mitral valve repair remains limited in Asian populations. We compared Custodiol in minimally invasive mitral valve repair to repetitive cold blood cardioplegia in open mitral valve repair. METHODS: We retrospectively evaluated 98 consecutive patients who underwent minimally invasive mitral valve repair with Custodiol and 70 consecutive patients who underwent open mitral valve repair with repetitive cold blood cardioplegia at our institution between January 2015 and December 2024. The primary endpoints were creatine kinase-myocardial band (MB) levels and left ventricular ejection fraction determined by echocardiography pre- and post-surgery. RESULTS: Maximum creatine kinase-MB levels within 48 h post-surgery were significantly lower in the minimally invasive group than in the open repair group, both in the overall cohort (45.0 vs. 60.7 U/L; p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan.
- Department of Clinical Engineering, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan.
Zitieren
APA
Aizawa, H., Yoshitake, A., Katsunori, Y., Kinoshita, O., Kumagai, Y., Kuroda, T., Kanazawa, Y., Gatate, Y., Gyoten, T., & Asakura, T. (2026). Safety of Custodiol for Myocardial Protection in Minimally Invasive Mitral Valve Repair: A Japanese Single-Center Retrospective Comparison with Blood Cardioplegia in Conventional Sternotomy Repair. Annals of Thoracic and Cardiovascular Surgery. https://doi.org/10.5761/atcs.oa.25-00208
Vancouver
Aizawa H, Yoshitake A, Katsunori Y, Kinoshita O, Kumagai Y, Kuroda T, et al. Safety of Custodiol for Myocardial Protection in Minimally Invasive Mitral Valve Repair: A Japanese Single-Center Retrospective Comparison with Blood Cardioplegia in Conventional Sternotomy Repair. Annals of Thoracic and Cardiovascular Surgery. 2026. doi:10.5761/atcs.oa.25-00208
BibTeX
@article{Aizawa2026,
author = {Aizawa, Hiroaki and Yoshitake, Akihiro and Katsunori, Yuki and Kinoshita, Osamu and Kumagai, Yu and Kuroda, Taro and Kanazawa, Yuta and Gatate, Yuko and Gyoten, Takayuki and Asakura, Toshihisa},
title = {Safety of Custodiol for Myocardial Protection in Minimally Invasive Mitral Valve Repair: A Japanese Single-Center Retrospective Comparison with Blood Cardioplegia in Conventional Sternotomy Repair},
journal = {Annals of Thoracic and Cardiovascular Surgery},
year = {2026},
doi = {10.5761/atcs.oa.25-00208}
}
EUVIMED