Fachartikel in der Zeitschrift Annals of Thoracic and Cardiovascular Surgery, 2024. Verfasst von Yukio Umeda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular and Thoracic Surgery, Gifu Prefectural General Medical Center, Gifu, Gifu, Japan. Hauptthemen laut MEDLINE: Aortic Dissection, Blood Vessel Prosthesis Implantation, Feasibility Studies, Length of Stay. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Achieving a secure anastomosis and complete hemostasis is essential for surgically treating type A acute aortic dissection (TAAAD). This study assessed the clinical feasibility of "tailored stand-up collar (TSC)" technique for constructing the distal stump. METHODS: We enrolled 68 patients who underwent ascending aortic repair for TAAAD. Patients were categorized according to the technique for distal stump construction: conventional (C) group using only a felt strip (32 cases); post-aortotomy (P) group, with a Hydrofit-felt strip attached after aortotomy (18 cases), and TSC group, where a Hydrofit-felt strip attached during cooling (18 cases). Pre-operative characteristics, procedural profiles, and post-operative outcomes were evaluated. RESULTS: The pre-operative characteristics were identical among the groups. The durations of cardiopulmonary bypass, hemostasis, and surgery were significantly shorter in the P and TSC groups. The duration of open distal in the TSC group (21 min) was significantly shorter than the other two groups. Post-operative additional procedures were not required for the TSC group and their post-operative hospital stay was significantly shorter (47.1% of patients were discharged within 2 weeks). CONCLUSION: The TSC technique would be practical because of its high reproducibility in terms of ease of use, shorter anastomotic time, and secure hemostasis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic DissectionBlood Vessel Prosthesis ImplantationFeasibility StudiesLength of StayHumansFemaleMaleTreatment OutcomeMiddle AgedAgedTime FactorsAcute DiseaseRetrospective StudiesOperative TimeAortic AneurysmAortic Aneurysm, ThoracicAdultPostoperative Complications

Stichwörter der Autor:innen

Hydrofitdistal stump constructiontailored stand-up collar techniquetype A acute aortic dissection

Autor:innen und Institutionen

  • Department of Cardiovascular and Thoracic Surgery, Gifu Prefectural General Medical Center, Gifu, Gifu, Japan.
  • Department of Food and Nutritional Science, Toita Women's College, Tokyo, Japan.

Zitieren

APA

Umeda, Y., Inoue, Y., Mitta, S., Matsuno, Y., & Yoshikawa, S. (2024). Clinical Outcome of the Type A Acute Aortic Dissection Repair Using the “Tailored Stand-Up Collar” Technique. Annals of Thoracic and Cardiovascular Surgery. https://doi.org/10.5761/atcs.oa.23-00214

Vancouver

Umeda Y, Inoue Y, Mitta S, Matsuno Y, Yoshikawa S. Clinical Outcome of the Type A Acute Aortic Dissection Repair Using the “Tailored Stand-Up Collar” Technique. Annals of Thoracic and Cardiovascular Surgery. 2024. doi:10.5761/atcs.oa.23-00214

BibTeX
@article{Umeda2024,
  author = {Umeda, Yukio and Inoue, Yuta and Mitta, Shohei and Matsuno, Yukihiro and Yoshikawa, Shoji},
  title = {Clinical Outcome of the Type A Acute Aortic Dissection Repair Using the “Tailored Stand-Up Collar” Technique},
  journal = {Annals of Thoracic and Cardiovascular Surgery},
  year = {2024},
  doi = {10.5761/atcs.oa.23-00214}
}
Kostenlos starten →