Application of near-infrared spectroscopy for hay evaluation at different degrees of sample preparation
Animal Bioscience · 01.07.2024 · 37 (7) · 1196-1203
DOI: 10.5713/ab.23.0466 ↗Kurz gefasst
Fachartikel in der Zeitschrift Animal Bioscience, erschienen am 01.07.2024. Verfasst von Eun Chan Jeong und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of International Agricultural Technology, Seoul National University, Pyeongchang 25354, Korea. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Institute of Planning and Evaluation for Technology in Food, Agriculture, and Forestry, Ministry of Agriculture, Food and Rural Affairs, Hatch project fund.
Abstract (Originalsprache)
Objective
A study was conducted to quantify the performance differences of the nearinfrared spectroscopy (NIRS) calibration models developed with different degrees of hay sample preparations.
Methods
A total of 227 imported alfalfa (Medicago sativa L.) and another 360 imported timothy (Phleum pratense L.) hay samples were used to develop calibration models for nutrient value parameters such as moisture, neutral detergent fiber, acid detergent fiber, crude protein, and in vitro dry matter digestibility. Spectral data of hay samples prepared by milling into 1-mm particle size or unground were separately regressed against the wet chemistry results of the abovementioned parameters.
Results
The performance of the developed NIRS calibration models was evaluated based on R2, standard error, and ratio percentage deviation (RPD). The models developed with ground hay were more robust and accurate than those with unground hay based on calibration model performance indexes such as R2 (coefficient of determination), standard error, and RPD. Although the R2 of calibration models was mainly greater than 0.90 across the feed value indexes, the R2 of cross-validations was much lower. The R2 of cross-validation varies depending on feed value indexes, which ranged from 0.61 to 0.81 in alfalfa, and from 0.62 to 0.95 in timothy. Estimation of feed values in imported hay can be achievable by the calibrated NIRS. However, the NIRS calibration models must be improved by including a broader range of imported hay samples in the modeling.
Conclusion
Although the analysis accuracy of NIRS was substantially higher when calibration models were developed with ground samples, less sample preparation will be more advantageous for achieving rapid delivery of hay sample analysis results. Therefore, further research warrants investigating the level of sample preparations compromising analysis accuracy by NIRS.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of International Agricultural Technology, Seoul National University, Pyeongchang 25354, Korea.
- School of Plant, Environmental, and Soil Sciences, Louisiana State University, Agricultural Center, Baton Rouge, LA 70803, USA.
- Research Institute of Eco-friendly Livestock Science, Institute of GreenBio Science Technology, Seoul National University, Pyeongchang 25354, Korea.
Förderung
- Institute of Planning and Evaluation for Technology in Food, Agriculture, and Forestry
- Ministry of Agriculture, Food and Rural Affairs
- Hatch project fund
Zitieren
APA
Jeong, E. C., Han, K. J., Ahmadi, F., Li, Y. F., Wang, L. L., Yu, Y. S., & Kim, J. G. (2024). Application of near-infrared spectroscopy for hay evaluation at different degrees of sample preparation. Animal Bioscience, 37(7), 1196-1203. https://doi.org/10.5713/ab.23.0466
Vancouver
Jeong EC, Han KJ, Ahmadi F, Li YF, Wang LL, Yu YS, et al. Application of near-infrared spectroscopy for hay evaluation at different degrees of sample preparation. Animal Bioscience. 2024;37(7):1196-1203. doi:10.5713/ab.23.0466
BibTeX
@article{Jeong2024,
author = {Jeong, Eun Chan and Han, Kun Jun and Ahmadi, Farhad and Li, Yan Fen and Wang, Li Li and Yu, Young Sang and Kim, Jong Geun},
title = {Application of near-infrared spectroscopy for hay evaluation at different degrees of sample preparation},
journal = {Animal Bioscience},
year = {2024},
volume = {37},
number = {7},
pages = {1196--1203},
doi = {10.5713/ab.23.0466}
}
EUVIMED