Compensation of Time-of-Flight Drift Using an Internal Reference Ion during Long-Duration LIMAS Depth Profiling
Mass Spectrometry · 30.10.2026 · 15 (1) · A0201-A0201
DOI: 10.5702/massspectrometry.a0201 ↗Kurz gefasst
Fachartikel in der Zeitschrift Mass Spectrometry, erschienen am 30.10.2026. Verfasst von Ken-Ichi Bajo. Beteiligte Einrichtung: Department of Earth and Planetary Sciences, Faculty of Science, Hokkaido University, Sapporo 060-0810, Japan. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
In this study, the temporal behavior and compensation of time-of-flight (TOF) drift during long-duration depth profiling using Laser Ionization Mass Nanoscope (LIMAS) were investigated. Noble gas depth profiling by LIMAS requires detection of weak isotope signals with nanometer-scale depth resolution. However, such measurements often take several hours to a couple of days, during which TOF peak-position drift and statistical uncertainty may affect analytical precision. In this study, a 4He-implanted olivine substrate was analyzed as a test sample. The TOF spectra were processed by depth-layer stacking, peak extraction, and peak-position analysis. The 24Mg2+ peak was used as a matrix-derived internal reference to monitor and compensate for TOF drift. The peak-position shifts of measured ions showed clear linear correlations with the 24Mg2+ peak shift, indicating that the observed TOF drift is largely systematic. A 24Mg2+-based compensation reduced the peak-position fluctuations of the other ion species to less than 1 ns and improved the mass resolving power. These results demonstrate that the 24Mg2+ peak can be used as an internal reference for TOF drift compensation during long-duration measurements, providing a robust approach for micro- to nanoscale noble gas depth profiling using LIMAS.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Earth and Planetary Sciences, Faculty of Science, Hokkaido University, Sapporo 060-0810, Japan.
Zitieren
APA
Bajo, K. I. (2026). Compensation of Time-of-Flight Drift Using an Internal Reference Ion during Long-Duration LIMAS Depth Profiling. Mass Spectrometry, 15(1), A0201-A0201. https://doi.org/10.5702/massspectrometry.a0201
Vancouver
Bajo KI. Compensation of Time-of-Flight Drift Using an Internal Reference Ion during Long-Duration LIMAS Depth Profiling. Mass Spectrometry. 2026;15(1):A0201-A0201. doi:10.5702/massspectrometry.a0201
BibTeX
@article{Bajo2026,
author = {Bajo, Ken-Ichi},
title = {Compensation of Time-of-Flight Drift Using an Internal Reference Ion during Long-Duration LIMAS Depth Profiling},
journal = {Mass Spectrometry},
year = {2026},
volume = {15},
number = {1},
pages = {A0201--A0201},
doi = {10.5702/massspectrometry.a0201}
}
EUVIMED