A Preliminary Evaluation of a Depth-Weighted Geoelectrical Vulnerability Index for Basement Aquifer at Federal University of Health Sciences, Ila-Orangun
UMYU Scientifica · 29.06.2026 · 5 (2) · 323-335
DOI: 10.56919/usci.2652.030 ↗Kurz gefasst
Fachartikel in der Zeitschrift UMYU Scientifica, online erschienen am 29.06.2026. Verfasst von Warith Adewale Adebisi und 2 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Assessing intrinsic groundwater vulnerability in crystalline basement terrains remains challenging because conventional vulnerability approaches often fail to account for the vertical distribution of the protective subsurface layer. This study presents a depth-weighted geoelectric vulnerability index (DWGVI) designed to incorporate the depth-dependent effectiveness of protective layers in basement aquifer systems. Electrical resistivity data from thirty vertical electrical sounding (VES) points were quantitatively interpreted to derive layer resistivity and thickness parameters. The DWGVI was formulated using the depth-weighted Dar Zarrouk principle, while longitudinal conductance (S) was computed as a conventional indicator of aquifer protective capacity for comparison. Results reveal a multilayered basement aquifer system characterized by thin overburden and shallow fractured bedrock. Longitudinal conductance values ranged from 0.0155 to 0.1439 S, indicating predominantly weak to moderate protective capacity, whereas DWGVI values varied between 0.00744 and 0.06829 S/m. Following normalization, the derived vulnerability index delineated zones of very low, low, moderate, high and very high intrinsic vulnerability across the study area. Pearson correlation analysis revealed a statistically significant moderate positive relationship between DWGVI and longitudinal conductance ( ), while Spearman’s rank correlation indicated a stronger monotonic association ( ), suggesting that both indices respond similarly to variations in subsurface resistivity and thickness. However, because the proposed index has not been independently validated using hydrochemical or borehole datasets, its wider applicability requires further investigation in other crystalline basements. The findings demonstrate that incorporating depth-weighting significantly can improve the hydrogeological realism of geoelectrical vulnerability assessment in basement terrains.
Zitieren
APA
Adebisi, W. A., Olatunji, S., & Abubakar, H. O. (2026). A Preliminary Evaluation of a Depth-Weighted Geoelectrical Vulnerability Index for Basement Aquifer at Federal University of Health Sciences, Ila-Orangun. UMYU Scientifica, 5(2), 323-335. https://doi.org/10.56919/usci.2652.030
Vancouver
Adebisi WA, Olatunji S, Abubakar HO. A Preliminary Evaluation of a Depth-Weighted Geoelectrical Vulnerability Index for Basement Aquifer at Federal University of Health Sciences, Ila-Orangun. UMYU Scientifica. 2026;5(2):323-335. doi:10.56919/usci.2652.030
BibTeX
@article{Adebisi2026,
author = {Adebisi, Warith Adewale and Olatunji, Saminu and Abubakar, Hussain Olanrewaju},
title = {A Preliminary Evaluation of a Depth-Weighted Geoelectrical Vulnerability Index for Basement Aquifer at Federal University of Health Sciences, Ila-Orangun},
journal = {UMYU Scientifica},
year = {2026},
volume = {5},
number = {2},
pages = {323--335},
doi = {10.56919/usci.2652.030}
}
EUVIMED