Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?
Journal of Korean Dialysis Access · 2022
DOI: 10.56774/jkda22101 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Korean Dialysis Access, 2022. Verfasst von Sung Hwan Bae und 5 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
The purpose of this study is to identify feasibility of MILLER technique in patients with high-flow vascular access problem and to investigate the adequate balloon size. Materials and Methods:This retrospective study included 74 patients who received the MILLER banding procedure for high flow vascular access.All study subjects underwent measurement of pre-and post-banding vascular access flow rate using duplex Doppler ultrasonography.We randomly used an endoluminal balloon for the banding procedure among 3 mm, 4 mm, and 5 mm-sized balloons.And we classified patients into three groups according to balloon size.We compared the pre-banding vascular access flow rates and post-banding vascular access flow rates in three groups.
Results
Technical success rate is 97% (72/74).The ratios of decreasing flow less than 1,500 mL/min in 3 mm, 4 mm, and 5 mm balloon groups were 61.1% (11/18), 51.5% (17/33), and 23.8% (5/21), respectively.Mean values of the pre-banding Qa and post-banding Qa in patients with use of 3 mm balloon were 3,225.94±2,515.51mL/min and 1,300.83±707.24mL/min, respectively.The mean values of those in patients with use of 4 mm balloon were 3,476.81±2,684.74mL/min and 1,712.68±1,233mL/min, respectively, while the mean values of those in patients with use of 5 mm balloon were 3,815.14±1,851.55mL/min and 2,361.33±1,422.51mL/min.Statistically significant difference was demonstrated between groups of 3 mm and 5 mm balloon in post-banding Qa (p=0.004).
Conclusion
Banding adjustment with 3 mm balloon may be reasonable in MILLER banding for patients with highflow vascular access problem and also 5 mm balloon is not appropriate for MILLER banding.
Zitieren
APA
Bae, S. H., Goo, D. E., Kim, Y. J., Yang, S. B., Lee, W. H., & Lee, J. M. (2022). Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?. Journal of Korean Dialysis Access. https://doi.org/10.56774/jkda22101
Vancouver
Bae SH, Goo DE, Kim YJ, Yang SB, Lee WH, Lee JM. Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?. Journal of Korean Dialysis Access. 2022. doi:10.56774/jkda22101