EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?

Sung Hwan Bae, Dong Erk Goo, Yong Jae Kim, Seung Boo Yang, Woong Hee Lee, Jae Myeong Lee

Journal of Korean Dialysis Access · 2022

DOI: 10.56774/jkda22101 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Korean Dialysis Access, 2022. Verfasst von Sung Hwan Bae und 5 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The purpose of this study is to identify feasibility of MILLER technique in patients with high-flow vascular access problem and to investigate the adequate balloon size. Materials and Methods:This retrospective study included 74 patients who received the MILLER banding procedure for high flow vascular access.All study subjects underwent measurement of pre-and post-banding vascular access flow rate using duplex Doppler ultrasonography.We randomly used an endoluminal balloon for the banding procedure among 3 mm, 4 mm, and 5 mm-sized balloons.And we classified patients into three groups according to balloon size.We compared the pre-banding vascular access flow rates and post-banding vascular access flow rates in three groups.

Results

Technical success rate is 97% (72/74).The ratios of decreasing flow less than 1,500 mL/min in 3 mm, 4 mm, and 5 mm balloon groups were 61.1% (11/18), 51.5% (17/33), and 23.8% (5/21), respectively.Mean values of the pre-banding Qa and post-banding Qa in patients with use of 3 mm balloon were 3,225.94±2,515.51mL/min and 1,300.83±707.24mL/min, respectively.The mean values of those in patients with use of 4 mm balloon were 3,476.81±2,684.74mL/min and 1,712.68±1,233mL/min, respectively, while the mean values of those in patients with use of 5 mm balloon were 3,815.14±1,851.55mL/min and 2,361.33±1,422.51mL/min.Statistically significant difference was demonstrated between groups of 3 mm and 5 mm balloon in post-banding Qa (p=0.004).

Conclusion

Banding adjustment with 3 mm balloon may be reasonable in MILLER banding for patients with highflow vascular access problem and also 5 mm balloon is not appropriate for MILLER banding.

Zitieren

APA

Bae, S. H., Goo, D. E., Kim, Y. J., Yang, S. B., Lee, W. H., & Lee, J. M. (2022). Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?. Journal of Korean Dialysis Access. https://doi.org/10.56774/jkda22101

Vancouver

Bae SH, Goo DE, Kim YJ, Yang SB, Lee WH, Lee JM. Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?. Journal of Korean Dialysis Access. 2022. doi:10.56774/jkda22101

BibTeX
@article{Bae2022,
  author = {Bae, Sung Hwan and Goo, Dong Erk and Kim, Yong Jae and Yang, Seung Boo and Lee, Woong Hee and Lee, Jae Myeong},
  title = {Interventional Management of High Flow Hemodialysis Access (MILLER Technique): What Size of Balloon is Appropriate for the Procedure?},
  journal = {Journal of Korean Dialysis Access},
  year = {2022},