EUVIMEDEUVIMED entdecken
Crossref

Comparison of VITEK 2 and Bruker Microflex LT MALDI-TOF MS for Routine Bacterial Identification in a Tertiary Hospital

Talha Karabıyık, Ugur Demırpek, Süheyl Uçucu

New Trends in Medicine Sciences · 30.06.2026 · 7 (2) · 53-58

DOI: 10.56766/ntms.1862930 ↗

Kurz gefasst

Fachartikel in der Zeitschrift New Trends in Medicine Sciences, online erschienen am 30.06.2026. Verfasst von Talha Karabıyık und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To compare bacterial identification using the VITEK 2 Compact (bioMérieux) and Bruker Microflex LT matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems in routine clinical microbiology. This retrospective cross-sectional study included consecutive clinical isolates recovered between February and April 2022 from a 1355-bed academic center. Identification was performed using VITEK 2 GN/GP cards and the Bruker MALDI Biotyper workflow using a Microflex LT instrument. Identifications were compared at species and genus levels; concordance was defined as identical taxon names. Agreement was summarized as percent agreement (Wilson 95% confidence intervals (CI)) and Cohen’s kappa (κ); discordance was interpreted as between-system disagreement because no molecular adjudication was performed. A total of 1394 isolates were analyzed. Most isolates were obtained from urine-related specimens (n=563, 40.4%) and blood cultures (n=446, 32.0%). Species-level concordance between systems was 93.1% (95% CI, 91.7–94.3%; κ=0.923 (95% CI, 0.908–0.937)), and genus-level concordance was 98.3% (95% CI, 97.5–98.8%; κ=0.979 (95% CI, 0.970–0.987)). Among the 96 discordant species identifications, 72 (75.0%) occurred within the same genus, indicating disagreements concentrated in closely related taxa. The most frequent discordant pairs involved the Klebsiella genus and coagulase-negative Staphylococcus species; the single most common pair was Klebsiella pneumoniae versus Klebsiella variicola (n=12). VITEK 2 and Bruker Microflex LT MALDI-TOF MS demonstrated very high agreement for routine bacterial identification, with most discrepancies occurring among closely related taxa. When species-level precision is clinically critical (e.g., outbreaks or invasive infections), confirmatory approaches such as 16S rRNA sequencing and up-to-date databases may be required.

Zitieren

APA

Karabıyık, T., Demırpek, U., & Uçucu, S. (2026). Comparison of VITEK 2 and Bruker Microflex LT MALDI-TOF MS for Routine Bacterial Identification in a Tertiary Hospital. New Trends in Medicine Sciences, 7(2), 53-58. https://doi.org/10.56766/ntms.1862930

Vancouver

Karabıyık T, Demırpek U, Uçucu S. Comparison of VITEK 2 and Bruker Microflex LT MALDI-TOF MS for Routine Bacterial Identification in a Tertiary Hospital. New Trends in Medicine Sciences. 2026;7(2):53-58. doi:10.56766/ntms.1862930

BibTeX
@article{Karabyk2026,
  author = {Karabıyık, Talha and Demırpek, Ugur and Uçucu, Süheyl},
  title = {Comparison of VITEK 2 and Bruker Microflex LT MALDI-TOF MS for Routine Bacterial Identification in a Tertiary Hospital},
  journal = {New Trends in Medicine Sciences},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {53--58},
  doi = {10.56766/ntms.1862930}
}
Kostenlos starten →