EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access

Validation of automated detection of REM sleep without atonia using in-laboratory and in-home recordings

Daniel J Levendowski, Lana M Chahine, Simon J G Lewis, Thomas J Finstuen, Andrea Galbiati, Chris Berka, Sherri Mosovsky, Hersh Parikh, Jack Anderson, Christine M Walsh, Joyce K Lee-Iannotti, Thomas C Neylan und 3 weitere

Journal of Clinical Sleep Medicine · 2025

DOI: 10.5664/jcsm.11488 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Clinical Sleep Medicine, 2025. Verfasst von Daniel J Levendowski und 14 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Brain Monitoring, Carlsbad, California. Hauptthemen laut MEDLINE: Polysomnography, REM Sleep Behavior Disorder, Sleep, REM. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIA NIH HHS, NCRR NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STUDY OBJECTIVES: To evaluate the concordance between visual scoring and automated detection of rapid eye movement sleep without atonia (RSWA) and the validity and reliability of in-home automated-RSWA detection in patients with rapid eye movement sleep behavior disorder (RBD) and a control group. METHODS: Sleep Profiler signals were acquired during simultaneous in-laboratory polysomnography in 24 isolated patients with RBD. Chin and arm RSWA measures visually scored by an expert sleep technologist were compared to algorithms designed to automate RSWA detection. In a second cohort, the accuracy of automated-RSWA detection for discriminating between RBD and control group (n = 21 and 42, respectively) was assessed in multinight in-home recordings. RESULTS: For the in-laboratory studies, agreement between visual and auto-scored RSWA from the chin and arm were excellent, with intraclass correlations of 0.89 and 0.95, respectively, and substantial, based on Kappa scores of 0.68 and 0.74, respectively. For classification of patients with iRBD vs controls, specificities derived from auto-detected RSWA densities obtained from in-home recordings were 0.88 for the chin, 0.93 for the arm, and 0.90 for the chin or arm, while the sensitivities were 0.81, 0.81, and 0.86, respectively. The night-to-night consistencies of the respective auto-detected RSWA densities were good based on intraclass correlations of 0.81, 0.79, and 0.84, however some night-to-night disagreements in abnormal RSWA detection were observed. CONCLUSIONS: When compared to expert visual RSWA scoring, automated RSWA detection demonstrates promise for detection of RBD. The night-to-night reliability of chin- and arm-RSWA densities acquired in-home were equivalent. CITATION: Levendowski DJ, Chahine LM, Lewis SJG, et al. Validation of automated detection of REM sleep without atonia using in-laboratory and in-home recordings. J Clin Sleep Med. 2025;21(3):583-592.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolysomnographyREM Sleep Behavior DisorderSleep, REMHumansMaleFemaleReproducibility of ResultsMiddle AgedAgedAlgorithms

Stichwörter der Autor:innen

Parkinson’s diseaseREM sleep behavior disorderREM sleep without atoniaRSWAiRBDnight-to-night variability

Autor:innen und Institutionen

  • Advanced Brain Monitoring, Carlsbad, California.
  • University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Macquarie University, Sydney, New South Wales, Australia.
  • Mayo Clinic College of Medicine and Science, Rochester, Minnesota.
  • Universitá Vita-Salute San Raffaele, Milano, Italy.
  • University of Sydney, Sydney, New South Wales, Australia.

Förderung

  • NIA NIH HHS
  • NCRR NIH HHS

Zitieren

APA

Levendowski, D. J., Chahine, L. M., Lewis, S. J. G., Finstuen, T. J., Galbiati, A., Berka, C., Mosovsky, S., Parikh, H., Anderson, J., Walsh, C. M., Lee-Iannotti, J. K., Neylan, T. C., Strambi, L. F., Boeve, B. F., & St Louis, E. K. (2025). Validation of automated detection of REM sleep without atonia using in-laboratory and in-home recordings. Journal of Clinical Sleep Medicine. https://doi.org/10.5664/jcsm.11488

Vancouver

Levendowski DJ, Chahine LM, Lewis SJG, Finstuen TJ, Galbiati A, Berka C, et al. Validation of automated detection of REM sleep without atonia using in-laboratory and in-home recordings. Journal of Clinical Sleep Medicine. 2025. doi:10.5664/jcsm.11488

BibTeX
@article{Levendowski2025,
  author = {Levendowski, Daniel J and Chahine, Lana M and Lewis, Simon J G and Finstuen, Thomas J and Galbiati, Andrea and Berka, Chris and Mosovsky, Sherri and Parikh, Hersh and Anderson, Jack and Walsh, Christine M and Lee-Iannotti, Joyce K and Neylan, Thomas C and Strambi, Luigi Ferini and Boeve, Bradley F and St Louis, Erik K},
  title = {Validation of automated detection of REM sleep without atonia using in-laboratory and in-home recordings},
  journal = {Journal of Clinical Sleep Medicine},
  year = {2025},
  doi = {10.5664/jcsm.11488}
}
Kostenlos starten →