Fachartikel in der Zeitschrift Clinical and Experimental Reproductive Medicine, online erschienen am 01.07.2026. Verfasst von Charise Mae M Lavadia und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Reproductive Endocrinology and Infertility, Department of Obstetrics and Gynecology, Korea University Anam Hospital, Seoul, Republic of K….
Abstract (Originalsprache)
Objective
This study compared serum anti-Müllerian hormone (AMH) concentrations measured in capillary fingerstick and venous samples using the automated fluorescence immunoassay system (AFIAS) AMH assay and evaluated procedure-related discomfort.
Methods
We conducted a prospective paired-sample method-comparison study at Korea University Anam Hospital, Seoul, Republic of Korea, in October 2023. During a single clinic visit, paired venous and fingerstick blood samples were obtained from each participant. Serum AMH concentrations were measured with the AFIAS AMH assay, and all laboratory analyses were performed at EONE Laboratories, Incheon, Republic of Korea. Agreement between sampling methods was evaluated using Passing–Bablok regression, Bland–Altman analysis, Pearson and Spearman correlation coefficients, and the intraclass correlation coefficient (ICC). Procedure-related pain was assessed immediately after sampling using an 11-point numeric rating scale (NRS; 0=no pain, 10=worst pain imaginable).
Results
Overall, 90 women aged 25–46 years provided paired samples. Mean AMH concentrations were 2.74 ng/mL (range, 0.11 to 9.99) in venous samples and 3.42 ng/mL (range, 0.17 to 11.55) in fingerstick samples. Passing–Bablok regression indicated proportional bias (y=0.123+1.175x), with no significant deviation from linearity on the cumulative sum (CUSUM) test (p=0.07). Agreement and correlation were high (ICC=0.930; Pearson r=0.982; p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Reproductive Endocrinology and Infertility, Department of Obstetrics and Gynecology, Korea University Anam Hospital, Seoul, Republic of Korea.
- Department of Obstetrics and Gynecology, St. Luke's Medical Center, Manila, Philippines.
- Department of Laboratory Medicine, EONE Laboratories, Incheon, Republic of Korea.
- Division of Reproductive Endocrinology and Infertility, Department of Obstetrics and Gynecology, Korea University Anam Hospital, Seoul, Republic of Korea. ryukj@korea.ac.kr.
Zitieren
APA
Lavadia, C. M. M., Choi, J., Cho, S. M., Jeong, H. G., Ryu, K. J., & Park, H. (2026). Comparison of serum anti-Müllerian hormone concentrations measured in capillary fingerstick and venous samples from Korean reproductive-aged women. Clinical and Experimental Reproductive Medicine. https://doi.org/10.5653/cerm.2026.09124
Vancouver
Lavadia CMM, Choi J, Cho SM, Jeong HG, Ryu KJ, Park H. Comparison of serum anti-Müllerian hormone concentrations measured in capillary fingerstick and venous samples from Korean reproductive-aged women. Clinical and Experimental Reproductive Medicine. 2026. doi:10.5653/cerm.2026.09124
BibTeX
@article{Lavadia2026,
author = {Lavadia, Charise Mae M and Choi, Jaehoon and Cho, Su Min and Jeong, Hye Geong and Ryu, Ki-Jin and Park, Hyuntae},
title = {Comparison of serum anti-Müllerian hormone concentrations measured in capillary fingerstick and venous samples from Korean reproductive-aged women},
journal = {Clinical and Experimental Reproductive Medicine},
year = {2026},
doi = {10.5653/cerm.2026.09124}
}
EUVIMED