EUVIMEDEUVIMED entdecken
Crossref

Utilidad de reconstrucciones 3D de estudios tomográfico para nefrometría y planeación de nefrectomías parciales laparoscópicas asistidas por robot

Erick Alejandro Hernández-Méndez, Iván Azael Martínez-Alonso, José Gadú Campos-Salcedo

Revista de Sanidad Militar · 12.11.2024 · 78 (4)

DOI: 10.56443/r4qh1a84 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista de Sanidad Militar, online erschienen am 12.11.2024. Verfasst von Erick Alejandro Hernández-Méndez und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose: to compare the results of 2D and 3D nephrometries in patients treated with robotic-assisted laparoscopic partial nephrectomy (RALPN) and determine their association with perioperative complications. Methods: retrospective study in patients underwent RALPN from 01/2019 to 12/2021. Nephrometries (R.E.N.A.L. and Padua) with 2D and 3D images were performed using the 3D Slicer® program. We made regression models to associate both scales and their two dimensional or three-dimensional origin with the length of hospital stay (LHS), bleeding, and postoperative glomerular filtration rate (GFR). We performed ROC curves to detect sensitivity and specificity of both 2D and 3D scales with the appearance of perioperative complications.

Results

35 cases were included and there were no differences between the calculation of the 2D and 3D scales. In linear regressions of both scales, only an increase of 0.33 days of LHS was found for each increase in the Padua 3D score >6 points (p=0.047), in other parameters no differences were found. We calculated ROC curves for complications on both scales but the area under the curve did not identify significant findings Limitations: this is a retrospective study in a single center. Originality: first study that analyzes the utility of 3D reconstructions in RALPN.

Conclusions

No significant differences were found between the R.E.N.A.L. and Padua nephrometry scales in 2D and 3D models for perioperative complications, however a prospective study with a larger sample could demonstrate the usefulness of 3D reconstructions as preoperative planning of RALPN.

Zitieren

APA

Hernández-Méndez, E. A., Martínez-Alonso, I. A., & Campos-Salcedo, J. G. (2024). Utilidad de reconstrucciones 3D de estudios tomográfico para nefrometría y planeación de nefrectomías parciales laparoscópicas asistidas por robot. Revista de Sanidad Militar, 78(4). https://doi.org/10.56443/r4qh1a84

Vancouver

Hernández-Méndez EA, Martínez-Alonso IA, Campos-Salcedo JG. Utilidad de reconstrucciones 3D de estudios tomográfico para nefrometría y planeación de nefrectomías parciales laparoscópicas asistidas por robot. Revista de Sanidad Militar. 2024;78(4). doi:10.56443/r4qh1a84

BibTeX
@article{HernndezMndez2024,
  author = {Hernández-Méndez, Erick Alejandro and Martínez-Alonso, Iván Azael and Campos-Salcedo, José Gadú},
  title = {Utilidad de reconstrucciones 3D de estudios tomográfico para nefrometría y planeación de nefrectomías parciales laparoscópicas asistidas por robot},
  journal = {Revista de Sanidad Militar},
  year = {2024},
  volume = {78},
  number = {4},
  doi = {10.56443/r4qh1a84}
}
Kostenlos starten →