Improving cooling rate in a cold room by using a parametric study coupled with computational fluid dynamics

Wilmer Cruz Guayacundo, Natali López Mejía, Hugo Fabian Lobatón García, Dustin Tahisin Gómez Rodríguez

eVitroKhem · 01.01.2025 · 4 · 153

DOI: 10.56294/evk2025153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift eVitroKhem, online erschienen am 01.01.2025. Verfasst von Wilmer Cruz Guayacundo und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The cooling dynamics of fruits depend on the flow conditions around the biological material. Computational fluid dynamics (CFD) coupled with a design of experiments (DOE) was implemented to reveal how a design variable (bin open area) and an operational variable (cold air mass flow at the inlet) affect turbulence and therefore the cooling kinetics. The CFD model was first validated against experimental local velocities inside the bins with an error of 14% to later be used in the parametric study (simulated data was consistent with experimental data). A clear non-homogeneity in turbulence distribution (vertical stratification) was found and therefore different local cooling rates. For this cooling room, the bin located in the top are cooling faster (8.1 hour 7/8th cooling time) that the bin located in the bottom (14.7 hours 7/8th cooling time). A 65% reduction in the mass flow rate shows a 21% increment in 7/8th cooling time and 57% increment in the lateral bin open area with a constant the flow rate, shows 9% increments in the 7/8th cooling time but with a 2 hours (7/8th cooling time) reduction in the difference between the bin in the top and the bin in the bottom which implied better homogeneity.

Zitieren

APA

Guayacundo, W. C., Mejía, N. L., García, H. F. L., & Rodríguez, D. T. G. (2025). Improving cooling rate in a cold room by using a parametric study coupled with computational fluid dynamics. eVitroKhem, 4, 153. https://doi.org/10.56294/evk2025153

Vancouver

Guayacundo WC, Mejía NL, García HFL, Rodríguez DTG. Improving cooling rate in a cold room by using a parametric study coupled with computational fluid dynamics. eVitroKhem. 2025;4:153. doi:10.56294/evk2025153

BibTeX
@article{Guayacundo2025,
  author = {Guayacundo, Wilmer Cruz and Mejía, Natali López and García, Hugo Fabian Lobatón and Rodríguez, Dustin Tahisin Gómez},
  title = {Improving cooling rate in a cold room by using a parametric study coupled with computational fluid dynamics},
  journal = {eVitroKhem},
  year = {2025},
  volume = {4},
  pages = {153},
  doi = {10.56294/evk2025153}
}
Kostenlos starten →